| Error Code | Technical Meaning | Multimeter Specs |
|---|---|---|
| Immergas 01 | Lockout due to lack of ignition (No flame) | Minimum ionization: > 1.8 µA | Gas inlet pressure: 20 mbar |
| Immergas 02 | Safety thermostat intervention due to overtemperature | Safety limit thermostat: 0 Ξ© cold closed |
| Immergas 10 | Insufficient primary circuit water pressure | Minimum pressure switch contact: Closes at > 0.7 bar (0 Ξ©) |
| Immergas 11 | Smoke pressure switch failure (Eolo waterproof models) | Smoke pressure switch: NO at rest, NC (0 Ξ©) on |
| Immergas 27 | Insufficient water circulation in the primary | Immergas NTC probe at 25°C: 10 kΞ© |
π οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?
Check OEM & aftermarket availability for Immergas Replacement Sensor / Part:
Other Manufacturers & Fault Code Directories
vag84 codes
View all Immergas codes β
moto75 codes
View all Immergas codes β
bsh71 codes
View all Immergas codes β
bmw_group70 codes
View all Immergas codes β
boilers70 codes
View all Immergas codes β
ev_modern70 codes
View all Immergas codes β
ford_volvo_jlr70 codes
View all Immergas codes β
japanese_oem70 codes
View all Immergas codes β
korean_oem70 codes
View all Immergas codes β
mercedes_group70 codes
View all Immergas codes β
renault_nissan70 codes
View all Immergas codes β
stellantis70 codes
View all Immergas codes β
trucks_heavy70 codes
View all Immergas codes β
appliances_hvac69 codes
View all Immergas codes β
OBD2 / Multimarcas48 codes
View all Immergas codes β
universal_obd34 codes
View all Immergas codes β
Audi28 codes
View all Immergas codes β
OBD2 Motor23 codes
View all Immergas codes β