| appliances_hvac 1C | Error in el sensor of level of Water in Washing machine Samsung (1C / 1E): inspect si el tubito transparente of the pressure switch está suelto or pellizcado, clean la cámara of Air in la cuba or replace / change el pressure switch | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac 3C | Fault / Failure of giro of the motor in Washing machine Samsung (3C / 3E): in motores Digital Inverter without escobillas suele deberse a soldaduras frías in el Module Inverter PCB Lower; in motores universales, a escobillas gastadas | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac 3E | Ausencia of Signal tacométrica or sobrecorriente in el motor of lavado Samsung (3E / 3E1 / 3E2): inspect electrical connector of 6/10 pines of the motor, escobillas of carbón or Board / Plate inversora | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac 4C | Error of suministro of Water in Washing machine or Dishwasher Samsung (4C / 4E): Grifo closed, Filter of malla of entrada clogged / obstructed due to cal/arena or coil of the Solenoid valve abierta | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac 4E | Falta of water supply inlet al Drum in Washing machine Samsung (4E / 4C): clean la malla metálica of the toma trasera of the Washing machine and check and test que el cajetín of detergente no esté clogged / obstructed | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac 5C | Error of drenaje of Water in Washing machine Samsung (5C / 5E): Empty / Drain due to el tubito of emergencia Lower, clean el Filter of monedas/botones and replace la drain pump si suena or se traba | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac 5E | El aparato Samsung no consigue evacuar el Water of the Drum or cuba (5E / SE / nd): drain hose clogged / obstructed or rodete of the drain pump desgastado | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac A3 | level anormal of Water in la bandeja of recogida of condensados in indoor unit Daikin of Ducted or cassette (A3): clean el lodo of the boya flotador, desatascar la tubería of Drain or replace la bombita of condensados | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac A5 | Control of alta pressure in calefacción or protección antihielo in refrigeración in indoor unit Daikin (A5): clean a fondo los filtros of Air of the Split and la turbina interior, or replace la NTC thermistor probe of the Battery interior | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac A6 | Lockout / Blockage, overload or falta of Signal Hall in el motor of the Fan of the indoor unit Split Daikin (A6): check and test que el rodillo of the turbina gire suave with la mano; si está duro or no arranca, replace el motor Fan DC | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac AE | Sensor of fugas of Water activado in la bandeja Lower (AE / E1 in Dishwasher and Washing machines LG): Inclinar ligeramente el aparato to Empty / Drain la bandeja base and localizar la pérdida of Water | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac CH05 | Communication error between the indoor unit Split and la outdoor condenser unit in Air acondicionado LG Inverter (CH05 / 5 parpadeos): Cortar el circuit breaker 5 minutes, inspect el cable of communication in el terminal 3 and check and test los condensadores/fuente of the Board / Plate exterior | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac CH10 | Fault / Failure of Lockout / Blockage or ausencia of pulsos of the sensor Hall in el motor of the Fan of the indoor unit Split LG (CH10 / 1 parpadeo): replace el motor Fan BLDC interior | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac CH21 | Pico of sobrecorriente continua (DC Peak / IPM Fault) in el Module of potencia of the Board / Plate exterior of the Air acondicionado LG (CH21): inspect pasta Thermal of the disipador IPM, bobinados of the Compressor and Board / Plate inversora exterior | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac CH26 | Anomalía of posición or Lockout / Blockage of startup in el Compressor DC of the outdoor condenser unit in Air acondicionado and aerotermia LG Therma V (CH26) | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac CH38 | Detección of falta of refrigerant gas in Air acondicionado LG (CH38): Localizar la Leak of gas in las tuercas abocardadas of las tuberías of cobre, reparar el abocardado, hacer vacío and cargar el peso exacto of R32 or R410A with báscula | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac DC | Door abierta or Fault / Failure of Lockout / Blockage in Washing machine Samsung (dC / of / dC1 / ddc): check and test latch / lock firme of the escotilla principal (y of the ventanilla Upper AddWash) or replace el blocapuertas Electric | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac DE | Error of door latch switch in Washing machine LG (dE): Empujar firmemente el aro of the escotilla until oír el clic, inspect que la goma no pille ropa or replace el blocapuertas Electric | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac DE1 | La Door of the Washing machine LG está cerrada pero el microinterruptor of the blocapuertas no detecta el latch / lock Electric (replace blocapuertas dE1) | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac DE2 | El pestillo of the blocapuertas no consigue bloquear el gancho of the Door al iniciar el ciclo (Bisagra cedida or coil of the blocapuertas averiada dE2) | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac E10 | Problema of filling of Water in Washing machines AEG, Electrolux and Zanussi (E10 / E11 / C1): Grifo closed, Filter of malla of the toma trasera dirty / clogged or coil of the Solenoid valve abierta (~3.5β4.2 kΞ©) | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac E20 | Problema of Drain in Washing machine or secadora AEG, Electrolux and Zanussi (E20 / E21 / C2): clean el Filter of vaciado Lower and replace el motor of the Pump magnética of Drain si se atasca in caliente | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac E40 | Door abierta or Fault / Failure in el Lockout / Blockage of Door in Washing machine AEG, Electrolux and Zanussi (E40 / E41 / E42): Si la Door está bien cerrada pero flashes and no arranca, replace el blocapuertas Electric | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac E50 | Avería in el motor or su unidad of control in Washing machine or secadora AEG, Electrolux and Zanussi (E50 / E52 / E5E / E59): inspect desgaste of escobillas, coil of the tacogenerador or relés/IGBT of the Board / Plate inversora of the motor | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac E6 | Communication error between indoor unit and outdoor unit in Air Conditioners Midea, Carrier, Kaysun, Hisense, Giatsu and Mundoclima (E6 / E1): inspect continuidad of the cable of Signal S and fusible/fuente conmutada of the Board / Plate exterior | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac E60 | Fault / Failure of calentamiento (E60 / E62 / E66): in Washing machines indica resistance calefactora derivada a tierra or relé pegado. in Secadoras Pump of Calor indica overheat condition or Compressor/Fan dirty / clogged of pelusas | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac E70 | Fault / Failure in la NTC thermistor probe of temperature (E70 / E71 / E74 in AEG / Electrolux / Zanussi): Valor óhmico of the NTC thermistor probe out of range or Probe / Sensor desencajada of su alojamiento | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac E90 | Communication error or configuración electrónica between the Board / Plate principal and la Board / Plate of interfaz of the panel (E90 / E91 / E92 in AEG / Electrolux): Secar moisture in conectores or recodificar/replace / change Board / Plate | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac EC | Detección of Leak or falta of refrigerant gas in Air acondicionado Midea, Carrier, Kaysun, MDV and Baxi Anori (EC): El Evaporator interior no se enfría after arrancar el Compressor due to pérdida of gas or Probe / Sensor of Battery T2 descalibrada | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac EF0 | Aviso of seguridad AquaControl activado or exceso of espuma in Washing machine AEG / Electrolux (EF0 / EF3): Inclinar la Washing machine hacia atrás to Empty / Drain Water acumulada in la bandeja base and clean el Filter | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac ER-DH | Fault / Failure of desescarche in Refrigerator LG No-Frost (Er dH): El Evaporator no alcanza 8 °C after 1 hora of desescarche porque el fusible Thermal or la defrost heater element están fundidos | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac ER-FF | Error in el Fan of the congelador in Refrigerator LG No-Frost (Er FF): Aspas of the Fan bloqueadas due to acumulación of hielo after el panel of the congelador or motor of the Fan DC averiado | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac ER-IF | Error in el Fan of the conducto of the fábrica of hielo in Refrigerator americano LG (Er IF): Escarcha bloqueando el Fan of hielo or Fault / Failure Electric of the motor | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac F01 | En Washing machines Indesit/Hotpoint: short circuit in el triac of the motor of the main control board (PCB) or moisture in el electrical connector of the motor. in Dishwasher Whirlpool: NTC thermistor probe of temperature faulty | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac F02 | El motor no gira or el tacogenerador no envía Signal in Washing machine Indesit / Hotpoint / Ariston (F02): inspect desgaste of las motor carbon brushes and continuidad of the coil tacométrica (~115β180 Ξ©) | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac F05 | En Washing machines Indesit/Hotpoint: drain pump blocked / jammed or el pressure switch no detecta Drum vacío after drenar. in Washing machines Whirlpool: Fault / Failure in la NTC thermistor probe of temperature of the Water | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac F06 | En Dishwasher Whirlpool/Indesit (F6 / 6 parpadeos): No entra Water due to grifo closed, Solenoid valve or mass air flow (MAF) sensor. in Washing machines Whirlpool: Fault / Failure of Signal of the motor speed tachogenerator | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac F07 | En Dishwasher Whirlpool (F7 / 7 parpadeos): Fault / Failure in el water flow meter sensor Reed of impulsos of Water. in Washing machines Whirlpool: Triac of motor. in Indesit: resistance calefactora of lavado | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac F08 | Avería in el circuito of calentamiento in Washing machines Whirlpool, Indesit and Hotpoint (F08): resistance calefactora abierta or with derivación of insulation a masa/tierra due to moisture or cal | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac F09 | En Indesit/Hotpoint: Error of memoria EEPROM or configuración of firmware in la main control board (PCB). in Whirlpool: level of sobrellenado detectado due to el pressure switch | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac F12 | Ausencia of communication between the main control board (PCB) of potencia Lower and la Board / Plate of visualización/mandos of the panel frontal (En Whirlpool Also indica resistance calefactora pegada a masa) | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac F13 | En Lavasecadoras Indesit/Hotpoint/Ariston: Cable cortado in la NTC thermistor probe of temperature of the cámara Upper of secado (se parte due to las vibraciones of the Drum). in Whirlpool: Circuito of the blocapuertas Electric | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac F15 | En Lavasecadoras Indesit/Hotpoint: Fault / Failure in la resistance of secado or relé. in Dishwasher Hotpoint/Ariston/Indesit: Fault / Failure or Lockout / Blockage in la heating circulation pump/lavado principal BLAC | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac F18 | En Indesit/Hotpoint: Error interno of communication of the procesador DSP of control of the motor trifásico in Board / Plate. in Washing machines Whirlpool (F18 / Fod): Exceso of espuma que impide Empty / Drain | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac F24 | Fault / Failure in la detección of level of the pressure switch in Washing machine Whirlpool (F24): El contacto of sobrellenado permanece closed or la cámara of Air Lower of the Drum está clogged / obstructed due to lodo | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac F3 | temperature of the tubo of descarga of the Compressor exterior excesivamente alta in Air acondicionado Daikin (F3 > 120 °C): Causada due to falta of refrigerant gas (recalentamiento alto) or NTC thermistor probe of descarga descalibrada | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac FE | Error of sobrellenado of Water in Washing machine LG (FE): El Water sigue entrando incluso with la Washing machine parada porque la Solenoid valve of entrada se ha quedado atascada abierta (o due to exceso of espuma) | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac H6 | En Daikin (H6): Fault / Failure in el sensor of detección of posición of the rotor of the DC inverter compressor exterior. in Midea / Carrier / Kaysun / Johnson (H6): without Signal of retorno of velocidad of the motor of the Fan of the indoor unit Split | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac HC | Error of calentamiento of the Water in Washing machine Samsung (HC / HE / HE1 / E5): La resistance cerámica of the cuba está abierta due to cal (~25β28 Ξ©) or la NTC thermistor probe integrada está faulty | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac HE | Avería in el circuito of calentamiento of the Water (HE in LG): resistance calefactora quemada due to acumulación of cal (measure ~26 Ξ© with multímetro) or relé in la Board / Plate principal | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac I20 | Error of vaciado in Dishwasher AEG, Electrolux and Zanussi (i20 / 2 parpadeos): clean filtros, check and test la drain pump and desengrasar with Water caliente el conducto of the cámara of the sensor of pressure in el sumidero | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac I30 | Sistema antifugas AquaControl activado in Dishwasher AEG, Electrolux and Zanussi (i30 / 3 parpadeos): La drain pump funciona without parar porque hay Water in la bandeja Lower due to pérdida in un manguito or junta | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac IE | Error of water supply inlet in Washing machine or Dishwasher LG (No alcanza el level in 8 minutes): Abrir of the todo el grifo of pared, clean los filtros of malla of the manguera or replace / change la Solenoid valve of entrada | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac L5 | Sobrecorriente instantánea of salida in el Inverter of the Compressor exterior Daikin (L5): Desconectar los 3 cables U-V-W of the Compressor to measure si hay derivación a tierra; si el Compressor mide igual in sus 3 bobinados (~1β2 Ξ©), replace / change la Board / Plate inversora exterior | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac LC | Leak of Water detectada in la base in Washing machine or Dishwasher Samsung (LC / LC1 / LE / LE1): Secar el sensor of dos contactos of the bandeja Lower and inspect fugas in el manguito of the cajetín or fuelle | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac LE | Lockout / Blockage of the motor Direct Drive in Washing machine LG: El Drum intenta girar dando pequeños tirones and se to due to Fault / Failure in el sensor Hall of posición montado in el estátor of the motor or due to exceso of peso | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac OC | level of water overflow condition alcanzado (oC / OF / OE in Samsung): La Solenoid valve of entrada no corta el paso of Water or hay exceso of espuma in la cámara of the pressure switch | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac OE | Error of vaciado in Washing machine or Dishwasher LG: El Water no se evacúa in el time limit (Empty / Drain el tubito of emergencia, clean el Filter Lower atrapa-monedas or replace la Pump magnética of Drain) | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac P4 | En Midea/Carrier/Kaysun (P4): Fault / Failure of accionamiento of the DC inverter compressor DC due to avería in el Module IPM of the Board / Plate exterior. in Mitsubishi Electric (P4): Fault / Failure in el sensor flotador of drenaje of condensados | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac PE | Fault / Failure in el sensor of level of Water (electronic water level pressure switch PE in LG): inspect el electrical connector of 3 pines with sulfatación, soplar el tubito of goma hacia la cámara of Air or replace / change el pressure switch | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac PF | Corte of suministro Electric detectado For / During el ciclo (PF - Power Failure in LG): press Inicio/Pausa to reanudar; si ocurre continuamente without cortes of luz in casa, inspect el power plug and el Filter of red interno | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac SE | En Microondas/Hornos Samsung (SE / 5E): short circuit due to moisture in la membrana táctil of the teclado (clean electrical connector cinta or replace / change membrana). in Washing machines Samsung: Error of drenaje 5E | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac SUD | Exceso of espuma detectado in Washing machine Samsung (SUd / 5Ud / SD): La Washing machine hace pausas to disolver la espuma; usar menos detergente and clean el Filter Lower | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac TE | Fault / Failure in el sensor termistor NTC of temperature of the Water or of secado (tE in LG): electrical connector of the NTC thermistor probe suelto in la parte baja of the cuba or resistance out of range | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac U0 | Aviso of falta of refrigerant gas or Lockout / Blockage in el circuito Refrigerator in Air acondicionado and aerotermia Daikin (U0): check and test que las llaves of servicio exteriores estén abiertas, measure presiones of R32/R410A and inspect la coil of the valve of expansión EEV | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac U2 | voltage drop in la red Electric or subtensión in el circuito of the bus of Current continua (DC Bus) of the Board / Plate inversora exterior Daikin (U2): inspect condensadores electrolíticos of Filter of the Board / Plate exterior and voltage 230V | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac U4 | Fault / Failure of communication of Transmission between the indoor unit Split and la outdoor condenser unit in climatizador Daikin (U4): inspect apriete of the cable 3 of Signal in bornes 1-2-3 and check and test si la Board / Plate exterior enciende su LED verde of servicio | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac UC | Oscilación of voltaje in la red Electric (UC / 9C1 / 9E1 in Samsung < 175V or > 270V): Conectar directamente al power plug of pared without alargadores ni regletas múltiples | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
| appliances_hvac UE | Desequilibrio of carga For / During el centrifugado in Washing machine LG (uE / UE): Redistribuir prendas pesadas (edredones/toallas), nivelar las 4 patas contra el suelo or replace los 3 amortiguadores of the cuba | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |