Engineering Review: 2026-11-21 Β· SAE J2012 / IEC / OEM Verified
ESENDEFRIT
Boilers & Heating High Severity · Safety Lockout

Immergas Error Code 01: Meaning, Multimeter Diagnosis & Fix

Fault code 01 on Immergas units (Victrix Tera, Victrix Omnia, Victrix Exa, Eolo Mini, Eolo Star) indicates: Lockout due to lack of ignition (No flame). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Immergas 01)

Manufacturer / BrandImmergas
Error Code01
System / CategoryBoilers & Heating
Compatible ModelsVictrix Tera, Victrix Omnia, Victrix Exa, Eolo Mini, Eolo Star
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsMinimum ionization: > 1.8 µA | Gas inlet pressure: 20 mbar

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Is your boiler a condensing boiler (Victrix range) and is it dripping or bubbling?
βœ“ Scenario A: Yes (Confirmed)

The condensate collection siphon is clogged by aluminum sludge, flooding the combustion chamber and extinguishing the spark.

βœ• Scenario B: No (Not Present)

There is no gas supply or the ionization electrode is covered with white slag.

3. Step-by-Step Multimeter Testing Procedure (01)

  1. Safety Power Isolation: Disconnect the Immergas unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault 01 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Minimum ionization: > 1.8 µA | Gas inlet pressure: 20 mbar.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Immergas Error 01

πŸ”„ Immergas 01 Reset: Press the 'Reset' button once. After 5 consecutive attempts you have to turn off the power.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Ignition & Flame Electrode)?

Check OEM & aftermarket availability for Immergas Ignition & Flame Electrode:

Want to use the interactive diagnostic wizard or electrical calculators for Immergas 01?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Immergas Error Code 01

What does Immergas error code 01 mean?

Immergas 01: Lockout due to lack of ignition (No flame) (Victrix Tera, Victrix Omnia, Victrix Exa, Eolo Mini, Eolo Star). Multimeter Specs: Minimum ionization: > 1.8 µA | Gas inlet pressure: 20 mbar.

How do I reset Immergas fault code 01?

Press the 'Reset' button once. After 5 consecutive attempts you have to turn off the power.

What multimeter values should I check for Immergas code 01?

Minimum ionization: > 1.8 µA | Gas inlet pressure: 20 mbar