Fault code 01 on Immergas units (Victrix Tera, Victrix Omnia, Victrix Exa, Eolo Mini, Eolo Star) indicates: Lockout due to lack of ignition (No flame). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.
1. Technical Specifications & Multimeter Values (Immergas 01)
| Manufacturer / Brand | Immergas |
|---|---|
| Error Code | 01 |
| System / Category | Boilers & Heating |
| Compatible Models | Victrix Tera, Victrix Omnia, Victrix Exa, Eolo Mini, Eolo Star |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | Minimum ionization: > 1.8 µA | Gas inlet pressure: 20 mbar |
2. Guided Symptom Troubleshooting Matrix
π Is your boiler a condensing boiler (Victrix range) and is it dripping or bubbling?
β Scenario A: Yes (Confirmed)
The condensate collection siphon is clogged by aluminum sludge, flooding the combustion chamber and extinguishing the spark.
β Scenario B: No (Not Present)
There is no gas supply or the ionization electrode is covered with white slag.
3. Step-by-Step Multimeter Testing Procedure (01)
- Safety Power Isolation: Disconnect the Immergas unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault 01 for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Minimum ionization: > 1.8 µA | Gas inlet pressure: 20 mbar.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Immergas Error 01
π Immergas 01 Reset: Press the 'Reset' button once. After 5 consecutive attempts you have to turn off the power.
π οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Ignition & Flame Electrode)?
Check OEM & aftermarket availability for Immergas Ignition & Flame Electrode:
Want to use the interactive diagnostic wizard or electrical calculators for Immergas 01?
β‘ Open in Interactive Simulator β
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Immergas Error Code 01
What does Immergas error code 01 mean?
Immergas 01: Lockout due to lack of ignition (No flame) (Victrix Tera, Victrix Omnia, Victrix Exa, Eolo Mini, Eolo Star). Multimeter Specs: Minimum ionization: > 1.8 µA | Gas inlet pressure: 20 mbar.
How do I reset Immergas fault code 01?
Press the 'Reset' button once. After 5 consecutive attempts you have to turn off the power.
What multimeter values should I check for Immergas code 01?
Minimum ionization: > 1.8 µA | Gas inlet pressure: 20 mbar