Immergas Error Code 27: Meaning, Multimeter Diagnosis & Fix

Fault code 27 on Immergas units (Victrix Tera, Victrix Omnia, Victrix Exa, Eolo Mini, Eolo Star) indicates: Insufficient water circulation in the primary. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Immergas 27)

Manufacturer / BrandImmergas
Error Code27
System / CategoryBoilers & Heating
Compatible ModelsVictrix Tera, Victrix Omnia, Victrix Exa, Eolo Mini, Eolo Star
Severity LevelMedium Severity · Protection Mode
Multimeter SpecsImmergas NTC probe at 25°C: 10 kΩ

2. Guided Symptom Troubleshooting Matrix

🔎 Does the temperature on the screen suddenly rise to 85°C in 5 seconds?
✓ Scenario A: Yes (Confirmed)

The return filter is clogged by black sludge from the radiators or the pump rotates without force (worn condenser).

✕ Scenario B: No (Not Present)

Primary exchanger clogged by lime.

3. Step-by-Step Multimeter Testing Procedure (27)

  1. Safety Power Isolation: Disconnect the Immergas unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault 27 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Immergas NTC probe at 25°C: 10 kΩ.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Immergas Error 27

🔄 Immergas 27 Reset: Clean the heating filter and press 'Reset'.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (NTC Temperature Sensor)?

Check OEM & aftermarket availability for Immergas NTC Temperature Sensor:

Want to use the interactive diagnostic wizard or electrical calculators for Immergas 27?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Immergas Error Code 27

What does Immergas error code 27 mean?

Immergas 27: Insufficient water circulation in the primary (Victrix Tera, Victrix Omnia, Victrix Exa, Eolo Mini, Eolo Star). Multimeter Specs: Immergas NTC probe at 25°C: 10 kΩ.

How do I reset Immergas fault code 27?

Clean the heating filter and press 'Reset'.

What multimeter values should I check for Immergas code 27?

Immergas NTC probe at 25°C: 10 kΩ