Immergas Error Code 10: Meaning, Multimeter Diagnosis & Fix

Fault code 10 on Immergas units (Victrix Tera, Victrix Omnia, Victrix Exa, Eolo Mini, Eolo Star) indicates: Insufficient primary circuit water pressure. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Immergas 10)

Manufacturer / BrandImmergas
Error Code10
System / CategoryBoilers & Heating
Compatible ModelsVictrix Tera, Victrix Omnia, Victrix Exa, Eolo Mini, Eolo Star
Severity LevelLow Severity · Maintenance Advisory
Multimeter SpecsMinimum pressure switch contact: Closes at > 0.7 bar (0 Ω)

2. Guided Symptom Troubleshooting Matrix

🔎 Is the needle of the lower pressure gauge in the gray zone (< 0.6 bar)?
✓ Scenario A: Yes (Confirmed)

Turn the lower fill knob counterclockwise until the needle reaches 1.2 - 1.5 bar.

✕ Scenario B: No (Not Present)

Absolute water pressure switch clogged or with loose connector.

3. Step-by-Step Multimeter Testing Procedure (10)

  1. Safety Power Isolation: Disconnect the Immergas unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault 10 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Minimum pressure switch contact: Closes at > 0.7 bar (0 Ω).
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Immergas Error 10

🔄 Immergas 10 Reset: It disappears automatically when reaching 1.2 bar.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (Pressure Switch)?

Check OEM & aftermarket availability for Immergas Pressure Switch:

Want to use the interactive diagnostic wizard or electrical calculators for Immergas 10?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Immergas Error Code 10

What does Immergas error code 10 mean?

Immergas 10: Insufficient primary circuit water pressure (Victrix Tera, Victrix Omnia, Victrix Exa, Eolo Mini, Eolo Star). Multimeter Specs: Minimum pressure switch contact: Closes at > 0.7 bar (0 Ω).

How do I reset Immergas fault code 10?

It disappears automatically when reaching 1.2 bar.

What multimeter values should I check for Immergas code 10?

Minimum pressure switch contact: Closes at > 0.7 bar (0 Ω)