Boilers & Heating High Severity · Safety Lockout

Immergas Error Code 02: Meaning, Multimeter Diagnosis & Fix

Fault code 02 on Immergas units (Victrix Tera, Victrix Omnia, Victrix Exa, Eolo Mini, Eolo Star) indicates: Safety thermostat intervention due to overtemperature. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Immergas 02)

Manufacturer / BrandImmergas
Error Code02
System / CategoryBoilers & Heating
Compatible ModelsVictrix Tera, Victrix Omnia, Victrix Exa, Eolo Mini, Eolo Star
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsSafety limit thermostat: 0 Ω cold closed

2. Guided Symptom Troubleshooting Matrix

🔎 Is the boiler body very hot but the tubes are not?
✓ Scenario A: Yes (Confirmed)

Circulator pump blocked after being stopped in summer. Unlock the rotor with a screwdriver.

✕ Scenario B: No (Not Present)

Air trapped in the primary exchanger or open limit thermostat.

3. Step-by-Step Multimeter Testing Procedure (02)

  1. Safety Power Isolation: Disconnect the Immergas unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault 02 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Safety limit thermostat: 0 Ω cold closed.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Immergas Error 02

🔄 Immergas 02 Reset: Wait 15 minutes for it to cool and press 'Reset'.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Immergas Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Immergas 02?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Immergas Error Code 02

What does Immergas error code 02 mean?

Immergas 02: Safety thermostat intervention due to overtemperature (Victrix Tera, Victrix Omnia, Victrix Exa, Eolo Mini, Eolo Star). Multimeter Specs: Safety limit thermostat: 0 Ω cold closed.

How do I reset Immergas fault code 02?

Wait 15 minutes for it to cool and press 'Reset'.

What multimeter values should I check for Immergas code 02?

Safety limit thermostat: 0 Ω cold closed