Vaillant Error Code F27: Meaning, Multimeter Diagnosis & Fix

Fault code F27 on Vaillant units (ecoTEC Plus, ecoTEC Pro, turboTEC, atmoTEC) indicates: Parasitic flame detection (Detects flame with closed valve). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Vaillant F27)

Manufacturer / BrandVaillant
Error CodeF27
System / CategoryBoilers & Heating
Compatible ModelsecoTEC Plus, ecoTEC Pro, turboTEC, atmoTEC
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsElectrode-chassis insulation: > 20 MΩ dry

2. Guided Symptom Troubleshooting Matrix

🔎 Does F27 come out with no real flame inside the burner?
✓ Scenario A: Yes (Confirmed)

Moisture or ground fault in the ceramic of the ionization electrode or failure in the ionization amplifier on the plate.

✕ Scenario B: No (Not Present)

If there really is a small flame left on, the gas valve leaks and does not close the passage.

3. Step-by-Step Multimeter Testing Procedure (F27)

  1. Safety Power Isolation: Disconnect the Vaillant unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault F27 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Electrode-chassis insulation: > 20 MΩ dry.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Vaillant Error F27

🔄 Vaillant F27 Reset: Cut power for 1 minute and press Reset.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Vaillant Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Vaillant F27?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Vaillant Error Code F27

What does Vaillant error code F27 mean?

Vaillant F27: Parasitic flame detection (Detects flame with closed valve) (ecoTEC Plus, ecoTEC Pro, turboTEC, atmoTEC). Multimeter Specs: Electrode-chassis insulation: > 20 MΩ dry.

How do I reset Vaillant fault code F27?

Cut power for 1 minute and press Reset.

What multimeter values should I check for Vaillant code F27?

Electrode-chassis insulation: > 20 MΩ dry