Error Code Technical Meaning Multimeter Specs
Domusa / Roca Gavina (Gasóleo) A01 / Falta Water (Gavina / Atlas)Baja pressure hidráulica in el primary circuit of the Boiler of gasóleo (Error A01 / E04 / Parpadeo 0.3 bar)pressure of servicio in frío: 1.2 a 1.5 bar
Domusa / Roca Gavina (Gasóleo) E01 / Lockout / Blockage burner (Luz Roja)El burner of gasóleo se bloquea encendiendo el Button rojo of the caja of control (Falta of Flame or fotocélula sucia)Fotorresistencia burner (LDR): in oscuridad > 100 kΩ (OL) | Iluminada with linterna/Flame: baja a < 1.5 kΩ - 5 kΩ
Domusa / Roca Gavina (Gasóleo) E02 / STB overheat conditionDisparo of the high-limit safety thermostat límite (> 100°C - 110°C) due to falta of circulación or Pump blocked / jammedCondensador motor burner Riello/Domusa: 4.0 µF or 4.5 µF | pressure Pump gasoil Suntec: 11 a 12 bar