1. Technical Specifications & Multimeter Values (Domusa / Roca Gavina (Gasóleo) E01 / Lockout / Blockage burner (Luz Roja))
| Manufacturer / Brand | Domusa / Roca Gavina (Gasóleo) |
|---|---|
| Error Code | E01 / Lockout / Blockage burner (Luz Roja) |
| System / Category | Boilers & Heating |
| Compatible Models | Boilers of Gasóleo Domusa Sirena, Clima Plus, Evolution, Ferroli Atlas D, Roca Gavina GTI, Baxi Argenta |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | Fotorresistencia burner (LDR): in oscuridad > 100 kΩ (OL) | Iluminada with linterna/Flame: baja a < 1.5 kΩ - 5 kΩ |
2. Guided Symptom Troubleshooting Matrix
Permanent hardware or sensor circuit fault (El burner of gasóleo se bloquea encendiendo el Button rojo of the caja of control (Falta of Flame or fotocélula sucia)). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: Fotorresistencia burner (LDR): in oscuridad > 100 kΩ (OL) | Iluminada with linterna/Flame: baja a < 1.5 kΩ - 5 kΩ. If it reads open circuit (OL) or dead short, replace the faulty part.
Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: clean la lente of the fotorresistencia (fotocélula), purgar el Filter of gasóleo and press el Button rojo of the caja of control of the burner.
3. Step-by-Step Multimeter Testing Procedure (E01 / Lockout / Blockage burner (Luz Roja))
- Safety Power Isolation: Disconnect the Domusa / Roca Gavina (Gasóleo) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault E01 / Lockout / Blockage burner (Luz Roja) for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Fotorresistencia burner (LDR): in oscuridad > 100 kΩ (OL) | Iluminada with linterna/Flame: baja a < 1.5 kΩ - 5 kΩ.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Domusa / Roca Gavina (Gasóleo) Error E01 / Lockout / Blockage burner (Luz Roja)
Check OEM & aftermarket availability for Domusa Replacement Sensor / Part:
⚡ Open in Interactive Simulator →
5. Frequently Asked Questions: Domusa / Roca Gavina (Gasóleo) Error Code E01 / Lockout / Blockage burner (Luz Roja)
What does Domusa / Roca Gavina (Gasóleo) error code E01 / Lockout / Blockage burner (Luz Roja) mean?
Domusa / Roca Gavina (Gasóleo) E01 / Lockout / Blockage burner (Luz Roja): El burner of gasóleo se bloquea encendiendo el Button rojo of the caja of control (Falta of Flame or fotocélula sucia) (Boilers of Gasóleo Domusa Sirena, Clima Plus, Evolution, Ferroli Atlas D, Roca Gavina GTI, Baxi Argenta). Multimeter Specs: Fotorresistencia burner (LDR): in oscuridad > 100 kΩ (OL) | Iluminada with linterna/Flame: baja a < 1.5 kΩ - 5 kΩ.
How do I reset Domusa / Roca Gavina (Gasóleo) fault code E01 / Lockout / Blockage burner (Luz Roja)?
clean la lente of the fotorresistencia (fotocélula), purgar el Filter of gasóleo and press el Button rojo of the caja of control of the burner.
What multimeter values should I check for Domusa / Roca Gavina (Gasóleo) code E01 / Lockout / Blockage burner (Luz Roja)?
Fotorresistencia burner (LDR): in oscuridad > 100 kΩ (OL) | Iluminada with linterna/Flame: baja a < 1.5 kΩ - 5 kΩ