Domusa / Roca Gavina (Gasóleo) Error Code E02 / STB overheat condition: Meaning, Multimeter Diagnosis & Fix

Fault code E02 / STB overheat condition on Domusa / Roca Gavina (Gasóleo) units (Boilers of Gasóleo Domusa Sirena, Clima Plus, Evolution, Ferroli Atlas D, Roca Gavina GTI, Baxi Argenta) indicates: Disparo of the high-limit safety thermostat límite (> 100°C - 110°C) due to falta of circulación or Pump blocked / jammed. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Domusa / Roca Gavina (Gasóleo) E02 / STB overheat condition)

Manufacturer / BrandDomusa / Roca Gavina (Gasóleo)
Error CodeE02 / STB overheat condition
System / CategoryBoilers & Heating
Compatible ModelsBoilers of Gasóleo Domusa Sirena, Clima Plus, Evolution, Ferroli Atlas D, Roca Gavina GTI, Baxi Argenta
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsCondensador motor burner Riello/Domusa: 4.0 µF or 4.5 µF | pressure Pump gasoil Suntec: 11 a 12 bar

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does Domusa / Roca Gavina (Gasóleo) error code E02 / STB overheat condition return immediately after a full power cycle even when main supply voltage is stable?
βœ“ Scenario A: Yes (Confirmed)

Permanent hardware or sensor circuit fault (Disparo of the high-limit safety thermostat límite (> 100°C - 110°C) due to falta of circulación or Pump blocked / jammed). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: Condensador motor burner Riello/Domusa: 4.0 µF or 4.5 µF | pressure Pump gasoil Suntec: 11 a 12 bar. If it reads open circuit (OL) or dead short, replace the faulty part.

βœ• Scenario B: No (Not Present)

Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: Desbloquear el eje of the Pump circuladora, dejar enfriar la Boiler and press el Button oculto bajo el tapón negro of the high-limit safety thermostat.

3. Step-by-Step Multimeter Testing Procedure (E02 / STB overheat condition)

  1. Safety Power Isolation: Disconnect the Domusa / Roca Gavina (Gasóleo) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault E02 / STB overheat condition for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Condensador motor burner Riello/Domusa: 4.0 µF or 4.5 µF | pressure Pump gasoil Suntec: 11 a 12 bar.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Domusa / Roca Gavina (Gasóleo) Error E02 / STB overheat condition

πŸ”„ Domusa / Roca Gavina (Gasóleo) E02 / STB overheat condition Reset: Desbloquear el eje of the Pump circuladora, dejar enfriar la Boiler and press el Button oculto bajo el tapón negro of the high-limit safety thermostat.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Motor Run Capacitor)?

Check OEM & aftermarket availability for Domusa Motor Run Capacitor:

Want to use the interactive diagnostic wizard or electrical calculators for Domusa / Roca Gavina (Gasóleo) E02 / STB overheat condition?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Domusa / Roca Gavina (Gasóleo) Error Code E02 / STB overheat condition

What does Domusa / Roca Gavina (Gasóleo) error code E02 / STB overheat condition mean?

Domusa / Roca Gavina (Gasóleo) E02 / STB overheat condition: Disparo of the high-limit safety thermostat límite (> 100°C - 110°C) due to falta of circulación or Pump blocked / jammed (Boilers of Gasóleo Domusa Sirena, Clima Plus, Evolution, Ferroli Atlas D, Roca Gavina GTI, Baxi Argenta). Multimeter Specs: Condensador motor burner Riello/Domusa: 4.0 µF or 4.5 µF | pressure Pump gasoil Suntec: 11 a 12 bar.

How do I reset Domusa / Roca Gavina (Gasóleo) fault code E02 / STB overheat condition?

Desbloquear el eje of the Pump circuladora, dejar enfriar la Boiler and press el Button oculto bajo el tapón negro of the high-limit safety thermostat.

What multimeter values should I check for Domusa / Roca Gavina (Gasóleo) code E02 / STB overheat condition?

Condensador motor burner Riello/Domusa: 4.0 µF or 4.5 µF | pressure Pump gasoil Suntec: 11 a 12 bar