Domusa / Roca Gavina (Gasóleo) Error Code A01 / Falta Water (Gavina / Atlas): Meaning, Multimeter Diagnosis & Fix

Fault code A01 / Falta Water (Gavina / Atlas) on Domusa / Roca Gavina (Gasóleo) units (Boilers of Gasóleo Domusa Sirena, Clima Plus, Evolution, Ferroli Atlas D, Roca Gavina GTI, Baxi Argenta) indicates: Baja pressure hidráulica in el primary circuit of the Boiler of gasóleo (Error A01 / E04 / Parpadeo 0.3 bar). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Domusa / Roca Gavina (Gasóleo) A01 / Falta Water (Gavina / Atlas))

Manufacturer / BrandDomusa / Roca Gavina (Gasóleo)
Error CodeA01 / Falta Water (Gavina / Atlas)
System / CategoryBoilers & Heating
Compatible ModelsBoilers of Gasóleo Domusa Sirena, Clima Plus, Evolution, Ferroli Atlas D, Roca Gavina GTI, Baxi Argenta
Severity LevelLow Severity · Maintenance Advisory
Multimeter Specspressure of servicio in frío: 1.2 a 1.5 bar

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does Domusa / Roca Gavina (Gasóleo) error code A01 / Falta Water (Gavina / Atlas) return immediately after a full power cycle even when main supply voltage is stable?
βœ“ Scenario A: Yes (Confirmed)

Permanent hardware or sensor circuit fault (Baja pressure hidráulica in el primary circuit of the Boiler of gasóleo (Error A01 / E04 / Parpadeo 0.3 bar)). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: pressure of servicio in frío: 1.2 a 1.5 bar. If it reads open circuit (OL) or dead short, replace the faulty part.

βœ• Scenario B: No (Not Present)

Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: Rellenar Water in el circuito of calefacción until 1.5 bar.

3. Step-by-Step Multimeter Testing Procedure (A01 / Falta Water (Gavina / Atlas))

  1. Safety Power Isolation: Disconnect the Domusa / Roca Gavina (Gasóleo) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault A01 / Falta Water (Gavina / Atlas) for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: pressure of servicio in frío: 1.2 a 1.5 bar.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Domusa / Roca Gavina (Gasóleo) Error A01 / Falta Water (Gavina / Atlas)

πŸ”„ Domusa / Roca Gavina (Gasóleo) A01 / Falta Water (Gavina / Atlas) Reset: Rellenar Water in el circuito of calefacción until 1.5 bar.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Domusa Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Domusa / Roca Gavina (Gasóleo) A01 / Falta Water (Gavina / Atlas)?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Domusa / Roca Gavina (Gasóleo) Error Code A01 / Falta Water (Gavina / Atlas)

What does Domusa / Roca Gavina (Gasóleo) error code A01 / Falta Water (Gavina / Atlas) mean?

Domusa / Roca Gavina (Gasóleo) A01 / Falta Water (Gavina / Atlas): Baja pressure hidráulica in el primary circuit of the Boiler of gasóleo (Error A01 / E04 / Parpadeo 0.3 bar) (Boilers of Gasóleo Domusa Sirena, Clima Plus, Evolution, Ferroli Atlas D, Roca Gavina GTI, Baxi Argenta). Multimeter Specs: pressure of servicio in frío: 1.2 a 1.5 bar.

How do I reset Domusa / Roca Gavina (Gasóleo) fault code A01 / Falta Water (Gavina / Atlas)?

Rellenar Water in el circuito of calefacción until 1.5 bar.

What multimeter values should I check for Domusa / Roca Gavina (Gasóleo) code A01 / Falta Water (Gavina / Atlas)?

pressure of servicio in frío: 1.2 a 1.5 bar