| Bosch AL | Freezer temperature alarm (Temporary cold loss) | Optimal freezer temperature: -18°C | Refrigerator: +4°C |
| Bosch Depósito Lleno | False water tank full alarm (Empty tray icon flashes with empty drawer) | Lint Mud Free Bottom Buoy | Lift pump: ~25W |
| Bosch E01 | Fault / Failure in el Module of potencia electrónica (Relé of Pump or Board / Plate quemada - E01 a E05) | Power supply Module potencia BSH: 230V AC |
| Bosch E0513 | Communication failure or voltage conflict at startup (Equivalent to E 05 13 / E) | Mains voltage between Phase and Neutral: 230V AC stable | Firm terminal bridges L1-L2 and N1-N2 |
| Bosch E0532 | Key blocked or dirt on the oven ring/touch panel | Clean and dry touch panel |
| Bosch E09 | Does not heat water: Heat pump (wash pump with integrated resistance) burnt out | BSH heat pump resistance (between the two thick red pins): 19 Ω - 22 Ω (If it gives infinite OL, it is burned) |
| Bosch E14 | Fault / Failure in el water flow meter sensor (Reed Switch): Water enters but pulses are not counted | Flow meter Reed switch: Opens and closes continuity (0 Ω ↔ OL) when the impeller spins |
| Bosch E15 | Water in the lower base: Aquastop anti-leak system activated (Faucet flashes) | Base buoy microswitch: Activated with only 100 ml of water |
| Bosch E16 | Door or hatch does not lock properly (F16 equivalent) | PTC thermal door lock: ~900 Ω - 1.5 kΩ between phase and neutral of the delay |
| Bosch E17 | Water inlet time exceeded (No water in - F17 equivalent) | Input solenoid valve resistance: 3.5 kΩ - 4.5 kΩ | Minimum network pressure: 1.0 bar |
| Bosch E18 | The washing machine does not drain water or takes too long to empty the drum (Equivalent F18) | Drain pump coil resistance: 150 Ω - 220 Ω | Max emptying time: 6 min |
| Bosch E19 | Heat exchanger valve failure (Dispenser / Side Drain Valve) | BSH exchanger valve resistance (modern DC version): ~1.5 kΩ - 2.2 kΩ |
| Bosch E2 | Faulty evaporator NTC probe (Freezer makes ice and stops cooling at the top) | Bosch/Balay refrigerator NTC probe at 25°C: 5 kΩ (at -18°C: ~43 kΩ) |
| Bosch E22 | Dirty or clogged sump filters | Clear tank filters |
| Bosch E23 | Aquastop anti-leak system activated (Water in the bottom tray - F23 equivalent) | Aquastop buoy microswitch: Switched contact when polystyrene float rises |
| Bosch E24 | Drain failure or loose pump cover (E25 equivalent) | Drain pump cover is mandatory to create hydraulic pressure |
| Bosch E305 | Pyrolytic door latch lock (Door does not open after pyrolysis) | Pyrolysis latch motor: 230V AC |
| Bosch E9 | Failure in the induction zone IGBT power module (E9 / E6) | IGBT (Gate-Collector-Emitter) pins: They must not present continuity (0 Ω) with each other |
| Bosch E90 | Failure in the power electronic circuit or compressor relay (E90 / E89) | Stable mains voltage without extension cords or multiple thieves |
| Bosch F2 | Cooking zone too hot: Safety shutdown due to overtemperature (F2 / F4) | NTC probe center induction coil at 25°C: ~100 kΩ | Bottom fan: 12V DC |
| Bosch F21 | Motor blocked or drum does not rotate (Brush wear / Triac - E21 equivalent) | Minimum carbon brush length: > 15 mm | Motor tachometer winding: 15 Ω - 30 Ω |
| Bosch U400 | Incorrect electrical connection: 400V surge applied to a 230V module | Maximum allowable voltage per single-phase module: 230V-240V AC |