Engineering Review: 2026-11-21 · SAE J2012 / IEC / OEM Verified
ESENDEFRIT
Refrigerators & Freezers Medium Severity · Protection Mode

Bosch Error Code E2: Meaning, Multimeter Diagnosis & Fix

Fault code E2 on Bosch units (NoFrost, VitaFresh, Serie 4, Serie 6, KGN36, KGN39 (Also Balay and Siemens)) indicates: Faulty evaporator NTC probe (Freezer makes ice and stops cooling at the top). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Refrigerators & Freezers subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Bosch E2)

Manufacturer / BrandBosch
Error CodeE2
System / CategoryRefrigerators & Freezers
Compatible ModelsNoFrost, VitaFresh, Serie 4, Serie 6, KGN36, KGN39 (Also Balay and Siemens)
Severity LevelMedium Severity · Protection Mode
Multimeter SpecsBosch/Balay refrigerator NTC probe at 25°C: 5 kΩ (at -18°C: ~43 kΩ)

2. Guided Symptom Troubleshooting Matrix

🔎 Is the freezer cold but the top of the refrigerator is hot (> 12°C)?
✓ Scenario A: Yes (Confirmed)

The NTC probe that is clamped to the aluminum pipe of the evaporator does not read the defrost temperature, so it does not activate the resistance and ice clogs the air duct upwards.

✕ Scenario B: No (Not Present)

Replace evaporator probe and defrost manually.

3. Step-by-Step Multimeter Testing Procedure (E2)

  1. Safety Power Isolation: Disconnect the Bosch unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault E2 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Bosch/Balay refrigerator NTC probe at 25°C: 5 kΩ (at -18°C: ~43 kΩ).
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Bosch Error E2

🔄 Bosch E2 Reset: Unplug for 24 hours with the doors open and replace the evaporator probe.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (NTC Temperature Sensor)?

Check OEM & aftermarket availability for Bosch NTC Temperature Sensor:

Want to use the interactive diagnostic wizard or electrical calculators for Bosch E2?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Bosch Error Code E2

What does Bosch error code E2 mean?

Bosch E2: Faulty evaporator NTC probe (Freezer makes ice and stops cooling at the top) (NoFrost, VitaFresh, Serie 4, Serie 6, KGN36, KGN39 (Also Balay and Siemens)). Multimeter Specs: Bosch/Balay refrigerator NTC probe at 25°C: 5 kΩ (at -18°C: ~43 kΩ).

How do I reset Bosch fault code E2?

Unplug for 24 hours with the doors open and replace the evaporator probe.

What multimeter values should I check for Bosch code E2?

Bosch/Balay refrigerator NTC probe at 25°C: 5 kΩ (at -18°C: ~43 kΩ)