Induction & Cooktops
High Severity · Safety Lockout
Bosch Error Code U400: Meaning, Multimeter Diagnosis & Fix
Fault code U400 on Bosch units (Serie 4, Serie 6, Serie 8, PerfectFry, PIE, PUE, PID (Also Balay and Siemens)) indicates: Incorrect electrical connection: 400V surge applied to a 230V module. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Induction & Cooktops subsystem falls outside factory tolerances.
1. Technical Specifications & Multimeter Values (Bosch U400)
| Manufacturer / Brand | Bosch |
|---|---|
| Error Code | U400 |
| System / Category | Induction & Cooktops |
| Compatible Models | Serie 4, Serie 6, Serie 8, PerfectFry, PIE, PUE, PID (Also Balay and Siemens) |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | Maximum allowable voltage per single-phase module: 230V-240V AC |
2. Guided Symptom Troubleshooting Matrix
π Have you just installed the plate in a home with three-phase installation?
β Scenario A: Yes (Confirmed)
You have connected two live phases instead of Phase + Neutral, putting 400V into the board. Disconnect immediately at the electrical panel to avoid bursting the varistors of the source.
β Scenario B: No (Not Present)
Bad wiring in the lower terminal strip of the plate.
3. Step-by-Step Multimeter Testing Procedure (U400)
- Safety Power Isolation: Disconnect the Bosch unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault U400 for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Maximum allowable voltage per single-phase module: 230V-240V AC.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Bosch Error U400
π Bosch U400 Reset: Correct the wiring on the strip according to the 1N~ (230V) diagram stuck under the plate.
π οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?
Check OEM & aftermarket availability for Bosch Replacement Sensor / Part:
Want to use the interactive diagnostic wizard or electrical calculators for Bosch U400?
β‘ Open in Interactive Simulator β
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Bosch Error Code U400
What does Bosch error code U400 mean?
Bosch U400: Incorrect electrical connection: 400V surge applied to a 230V module (Serie 4, Serie 6, Serie 8, PerfectFry, PIE, PUE, PID (Also Balay and Siemens)). Multimeter Specs: Maximum allowable voltage per single-phase module: 230V-240V AC.
How do I reset Bosch fault code U400?
Correct the wiring on the strip according to the 1N~ (230V) diagram stuck under the plate.
What multimeter values should I check for Bosch code U400?
Maximum allowable voltage per single-phase module: 230V-240V AC