Bosch Error Code F2: Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Bosch F2)
| Manufacturer / Brand | Bosch |
|---|---|
| Error Code | F2 |
| System / Category | Induction & Cooktops |
| Compatible Models | Serie 4, Serie 6, Serie 8, PerfectFry, PIE, PUE, PID (Also Balay and Siemens) |
| Severity Level | Low Severity · Maintenance Advisory |
| Multimeter Specs | NTC probe center induction coil at 25°C: ~100 kΩ | Bottom fan: 12V DC |
2. Guided Symptom Troubleshooting Matrix
It is a normal thermal protection to avoid burning the induction coil or the electronics. Remove the pot from that heat and wait 15 minutes without touching any buttons until the warning goes off.
If F2 comes out with the board completely cold, the lower cooling fan is clogged with grease or the NTC probe in the center of the inductor is open.
3. Step-by-Step Multimeter Testing Procedure (F2)
- Safety Power Isolation: Disconnect the Bosch unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault F2 for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: NTC probe center induction coil at 25°C: ~100 kΩ | Bottom fan: 12V DC.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Bosch Error F2
Check OEM & aftermarket availability for Bosch NTC Temperature Sensor:
⚡ Open in Interactive Simulator →
5. Frequently Asked Questions: Bosch Error Code F2
What does Bosch error code F2 mean?
Bosch F2: Cooking zone too hot: Safety shutdown due to overtemperature (F2 / F4) (Serie 4, Serie 6, Serie 8, PerfectFry, PIE, PUE, PID (Also Balay and Siemens)). Multimeter Specs: NTC probe center induction coil at 25°C: ~100 kΩ | Bottom fan: 12V DC.
How do I reset Bosch fault code F2?
Remove containers, wait for the glass to cool and turn on normally.
What multimeter values should I check for Bosch code F2?
NTC probe center induction coil at 25°C: ~100 kΩ | Bottom fan: 12V DC