Solar Inverters & Water Heaters Low Severity · Maintenance Advisory

Thermor / Atlantic Error Code Err 03 / W22: Meaning, Multimeter Diagnosis & Fix

Fault code Err 03 / W22 on Thermor / Atlantic units (Termos of Aerotermia Aeromax VM, Aeromax 4/5, Atlantic Explorer, Cointra Oasis) indicates: Probe / Sensor of temperature of the Evaporator (desescarche) abierta or in short circuit. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Solar Inverters & Water Heaters subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Thermor / Atlantic Err 03 / W22)

Manufacturer / BrandThermor / Atlantic
Error CodeErr 03 / W22
System / CategorySolar Inverters & Water Heaters
Compatible ModelsTermos of Aerotermia Aeromax VM, Aeromax 4/5, Atlantic Explorer, Cointra Oasis
Severity LevelLow Severity · Maintenance Advisory
Multimeter SpecsNTC thermistor probe Evaporator a 25°C: 10 kΩ

2. Guided Symptom Troubleshooting Matrix

🔎 Does Thermor / Atlantic error code Err 03 / W22 return immediately after a full power cycle even when main supply voltage is stable?
✓ Scenario A: Yes (Confirmed)

Permanent hardware or sensor circuit fault (Probe / Sensor of temperature of the Evaporator (desescarche) abierta or in short circuit). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: NTC thermistor probe Evaporator a 25°C: 10 kΩ. If it reads open circuit (OL) or dead short, replace the faulty part.

✕ Scenario B: No (Not Present)

Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: replace la NTC thermistor probe of the Evaporator Upper.

3. Step-by-Step Multimeter Testing Procedure (Err 03 / W22)

  1. Safety Power Isolation: Disconnect the Thermor / Atlantic unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Err 03 / W22 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: NTC thermistor probe Evaporator a 25°C: 10 kΩ.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Thermor / Atlantic Error Err 03 / W22

🔄 Thermor / Atlantic Err 03 / W22 Reset: replace la NTC thermistor probe of the Evaporator Upper.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (NTC Temperature Sensor)?

Check OEM & aftermarket availability for Thermor NTC Temperature Sensor:

Want to use the interactive diagnostic wizard or electrical calculators for Thermor / Atlantic Err 03 / W22?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Thermor / Atlantic Error Code Err 03 / W22

What does Thermor / Atlantic error code Err 03 / W22 mean?

Thermor / Atlantic Err 03 / W22: Probe / Sensor of temperature of the Evaporator (desescarche) abierta or in short circuit (Termos of Aerotermia Aeromax VM, Aeromax 4/5, Atlantic Explorer, Cointra Oasis). Multimeter Specs: NTC thermistor probe Evaporator a 25°C: 10 kΩ.

How do I reset Thermor / Atlantic fault code Err 03 / W22?

replace la NTC thermistor probe of the Evaporator Upper.

What multimeter values should I check for Thermor / Atlantic code Err 03 / W22?

NTC thermistor probe Evaporator a 25°C: 10 kΩ