Fronius Error Code State 307: Meaning, Multimeter Diagnosis & Fix

Fault code State 307 on Fronius units (Solar Inverters Primo, Symo, Gen24) indicates: Low DC voltage of solar panels (Low PV Voltage). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Solar Inverters & Water Heaters subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Fronius State 307)

Manufacturer / BrandFronius
Error CodeState 307
System / CategorySolar Inverters & Water Heaters
Compatible ModelsSolar Inverters Primo, Symo, Gen24
Severity LevelLow Severity · Maintenance Advisory
Multimeter SpecsFronius Primo starting voltage: > 80V DC

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does code 307 appear at dawn, dusk, or during very cloudy skies?
βœ“ Scenario A: Yes (Confirmed)

It is not a fault: there is simply little solar radiation and the panels have not yet reached the minimum 80V to start injecting energy. It will disappear only as soon as the sun rises.

βœ• Scenario B: No (Not Present)

If it reads 307 at 12 noon in full sun, an MC4 connector on the roof has been disconnected or the DC disconnector is turned off.

3. Step-by-Step Multimeter Testing Procedure (State 307)

  1. Safety Power Isolation: Disconnect the Fronius unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault State 307 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Fronius Primo starting voltage: > 80V DC.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Fronius Error State 307

πŸ”„ Fronius State 307 Reset: No action required at dawn/dusk; It automatically resets with solar radiation.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Fronius Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Fronius State 307?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Fronius Error Code State 307

What does Fronius error code State 307 mean?

Fronius State 307: Low DC voltage of solar panels (Low PV Voltage) (Solar Inverters Primo, Symo, Gen24). Multimeter Specs: Fronius Primo starting voltage: > 80V DC.

How do I reset Fronius fault code State 307?

No action required at dawn/dusk; It automatically resets with solar radiation.

What multimeter values should I check for Fronius code State 307?

Fronius Primo starting voltage: > 80V DC