Thermor / Atlantic Error Code Err 01 / W31: Meaning, Multimeter Diagnosis & Fix

Fault code Err 01 / W31 on Thermor / Atlantic units (Termos of Aerotermia Aeromax VM, Aeromax 4/5, Atlantic Explorer, Cointra Oasis) indicates: Probe / Sensor of temperature of the depósito of Water faulty (NTC thermistor probe out of range). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Solar Inverters & Water Heaters subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Thermor / Atlantic Err 01 / W31)

Manufacturer / BrandThermor / Atlantic
Error CodeErr 01 / W31
System / CategorySolar Inverters & Water Heaters
Compatible ModelsTermos of Aerotermia Aeromax VM, Aeromax 4/5, Atlantic Explorer, Cointra Oasis
Severity LevelMedium Severity · Protection Mode
Multimeter SpecsNTC thermistor probe Thermor/Atlantic a 25°C: 10 kΩ

2. Guided Symptom Troubleshooting Matrix

🔎 Does Thermor / Atlantic error code Err 01 / W31 return immediately after a full power cycle even when main supply voltage is stable?
✓ Scenario A: Yes (Confirmed)

Permanent hardware or sensor circuit fault (Probe / Sensor of temperature of the depósito of Water faulty (NTC thermistor probe out of range)). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: NTC thermistor probe Thermor/Atlantic a 25°C: 10 kΩ. If it reads open circuit (OL) or dead short, replace the faulty part.

✕ Scenario B: No (Not Present)

Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: replace la NTC thermistor probe of inmersión and apagar/encender el equipo.

3. Step-by-Step Multimeter Testing Procedure (Err 01 / W31)

  1. Safety Power Isolation: Disconnect the Thermor / Atlantic unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Err 01 / W31 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: NTC thermistor probe Thermor/Atlantic a 25°C: 10 kΩ.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Thermor / Atlantic Error Err 01 / W31

🔄 Thermor / Atlantic Err 01 / W31 Reset: replace la NTC thermistor probe of inmersión and apagar/encender el equipo.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (NTC Temperature Sensor)?

Check OEM & aftermarket availability for Thermor NTC Temperature Sensor:

Want to use the interactive diagnostic wizard or electrical calculators for Thermor / Atlantic Err 01 / W31?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Thermor / Atlantic Error Code Err 01 / W31

What does Thermor / Atlantic error code Err 01 / W31 mean?

Thermor / Atlantic Err 01 / W31: Probe / Sensor of temperature of the depósito of Water faulty (NTC thermistor probe out of range) (Termos of Aerotermia Aeromax VM, Aeromax 4/5, Atlantic Explorer, Cointra Oasis). Multimeter Specs: NTC thermistor probe Thermor/Atlantic a 25°C: 10 kΩ.

How do I reset Thermor / Atlantic fault code Err 01 / W31?

replace la NTC thermistor probe of inmersión and apagar/encender el equipo.

What multimeter values should I check for Thermor / Atlantic code Err 01 / W31?

NTC thermistor probe Thermor/Atlantic a 25°C: 10 kΩ