SMA Error Code Error 1302: Meaning, Multimeter Diagnosis & Fix

Fault code Error 1302 on SMA units (Sunny Boy SB 1.5 - 6.0, Sunny Tripower STP) indicates: Lack of grid voltage or missing phase at the AC output (Waiting for grid voltage). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Solar Inverters & Water Heaters subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (SMA Error 1302)

Manufacturer / BrandSMA
Error CodeError 1302
System / CategorySolar Inverters & Water Heaters
Compatible ModelsSunny Boy SB 1.5 - 6.0, Sunny Tripower STP
Severity LevelMedium Severity · Protection Mode
Multimeter SpecsRequired AC voltage: 230V AC / 50 Hz

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does the inverter flash and not inject, indicating that it is waiting for grid voltage?
βœ“ Scenario A: Yes (Confirmed)

The circuit breaker or differential in the inverter's AC protection electrical panel has tripped.

βœ• Scenario B: No (Not Present)

Turn up the AC automatic and verify with the multimeter that 230V AC reaches the AC terminal of the inverter.

3. Step-by-Step Multimeter Testing Procedure (Error 1302)

  1. Safety Power Isolation: Disconnect the SMA unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Error 1302 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Required AC voltage: 230V AC / 50 Hz.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear SMA Error Error 1302

πŸ”„ SMA Error 1302 Reset: Automatic reset 60 seconds after recovering the 230V AC mains.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for SMA Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for SMA Error 1302?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: SMA Error Code Error 1302

What does SMA error code Error 1302 mean?

SMA Error 1302: Lack of grid voltage or missing phase at the AC output (Waiting for grid voltage) (Sunny Boy SB 1.5 - 6.0, Sunny Tripower STP). Multimeter Specs: Required AC voltage: 230V AC / 50 Hz.

How do I reset SMA fault code Error 1302?

Automatic reset 60 seconds after recovering the 230V AC mains.

What multimeter values should I check for SMA code Error 1302?

Required AC voltage: 230V AC / 50 Hz