Sungrow Error Code Error 002 / 014: Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Sungrow Error 002 / 014)
| Manufacturer / Brand | Sungrow |
|---|---|
| Error Code | Error 002 / 014 |
| System / Category | Solar Inverters & Water Heaters |
| Compatible Models | Solar Inverters Residenciales and Hybrids SG2.0RS a SG10RS, SH3.0RS a SH10RT |
| Severity Level | Medium Severity · Protection Mode |
| Multimeter Specs | voltage Maximum corte red UNE/EN 50549: 253V AC |
2. Guided Symptom Troubleshooting Matrix
Permanent hardware or sensor circuit fault (Sobretensión or frecuencia of red out of range (Grid Overvoltage - Alarma 002 / 014)). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: voltage Maximum corte red UNE/EN 50549: 253V AC. If it reads open circuit (OL) or dead short, replace the faulty part.
Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: Se rearma automáticamente in cuanto la voltage of the calle baja of 250V AC.
3. Step-by-Step Multimeter Testing Procedure (Error 002 / 014)
- Safety Power Isolation: Disconnect the Sungrow unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault Error 002 / 014 for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: voltage Maximum corte red UNE/EN 50549: 253V AC.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Sungrow Error Error 002 / 014
Check OEM & aftermarket availability for Sungrow Replacement Sensor / Part:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Sungrow Error Code Error 002 / 014
What does Sungrow error code Error 002 / 014 mean?
Sungrow Error 002 / 014: Sobretensión or frecuencia of red out of range (Grid Overvoltage - Alarma 002 / 014) (Solar Inverters Residenciales and Hybrids SG2.0RS a SG10RS, SH3.0RS a SH10RT). Multimeter Specs: voltage Maximum corte red UNE/EN 50549: 253V AC.
How do I reset Sungrow fault code Error 002 / 014?
Se rearma automáticamente in cuanto la voltage of the calle baja of 250V AC.
What multimeter values should I check for Sungrow code Error 002 / 014?
voltage Maximum corte red UNE/EN 50549: 253V AC