Sungrow Error Code Error 002 / 014: Meaning, Multimeter Diagnosis & Fix

Fault code Error 002 / 014 on Sungrow units (Solar Inverters Residenciales and Hybrids SG2.0RS a SG10RS, SH3.0RS a SH10RT) indicates: Sobretensión or frecuencia of red out of range (Grid Overvoltage - Alarma 002 / 014). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Solar Inverters & Water Heaters subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Sungrow Error 002 / 014)

Manufacturer / BrandSungrow
Error CodeError 002 / 014
System / CategorySolar Inverters & Water Heaters
Compatible ModelsSolar Inverters Residenciales and Hybrids SG2.0RS a SG10RS, SH3.0RS a SH10RT
Severity LevelMedium Severity · Protection Mode
Multimeter Specsvoltage Maximum corte red UNE/EN 50549: 253V AC

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does Sungrow error code Error 002 / 014 return immediately after a full power cycle even when main supply voltage is stable?
βœ“ Scenario A: Yes (Confirmed)

Permanent hardware or sensor circuit fault (Sobretensión or frecuencia of red out of range (Grid Overvoltage - Alarma 002 / 014)). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: voltage Maximum corte red UNE/EN 50549: 253V AC. If it reads open circuit (OL) or dead short, replace the faulty part.

βœ• Scenario B: No (Not Present)

Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: Se rearma automáticamente in cuanto la voltage of the calle baja of 250V AC.

3. Step-by-Step Multimeter Testing Procedure (Error 002 / 014)

  1. Safety Power Isolation: Disconnect the Sungrow unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Error 002 / 014 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: voltage Maximum corte red UNE/EN 50549: 253V AC.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Sungrow Error Error 002 / 014

πŸ”„ Sungrow Error 002 / 014 Reset: Se rearma automáticamente in cuanto la voltage of the calle baja of 250V AC.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Sungrow Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Sungrow Error 002 / 014?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Sungrow Error Code Error 002 / 014

What does Sungrow error code Error 002 / 014 mean?

Sungrow Error 002 / 014: Sobretensión or frecuencia of red out of range (Grid Overvoltage - Alarma 002 / 014) (Solar Inverters Residenciales and Hybrids SG2.0RS a SG10RS, SH3.0RS a SH10RT). Multimeter Specs: voltage Maximum corte red UNE/EN 50549: 253V AC.

How do I reset Sungrow fault code Error 002 / 014?

Se rearma automáticamente in cuanto la voltage of the calle baja of 250V AC.

What multimeter values should I check for Sungrow code Error 002 / 014?

voltage Maximum corte red UNE/EN 50549: 253V AC