Sungrow · 5 Verified Diagnostic Sheets
ESENDEFRIT
Energía Solar

Sungrow Error Codes: Complete List (5 Faults), Causes & Reset

Complete technical directory of all 5 Sungrow error codes (Energía Solar) with exact meanings, multimeter reference specs, and reset instructions.

Error Code Technical Meaning Multimeter Specs
Sungrow Code 010 (Island / without Red Electric)El indicador LED of the Inverter Sungrow se pone in ROJO and in la app iSolarCloud aparece el Code of alarma '010 (Grid Off / Island)'El Inverter Sungrow realiza una cuenta atrás obligatoria of 60 seconds after recuperar los 230V AC antes of cerrar el relé of inyección
Sungrow Code 039 (Baja resistance of insulation Fotovoltaico)Alarma 'Code 039 (Low Insulation Resistance)' in Inverter Sungrow and no conecta a red in mañanas húmedasresistance of insulation solar normal in seco: > 10 MΩ (Alarma 039 salta si cae due to debajo of ~50 kΩ - 100 kΩ)
Sungrow Error 002 / 014Sobretensión or frecuencia of red out of range (Grid Overvoltage - Alarma 002 / 014)voltage Maximum corte red UNE/EN 50549: 253V AC
Sungrow Error 012Current of Leak excesiva (Leakage Current Fault / RCD Fault - Alarma 012)Current residual Maximum continua: < 30 mA (Picos < 300 mA)
Sungrow Error 039Low photovoltaic array insulation resistance to ground (Low Insulation Resistance - Alarma 039)resistance insulation Minimum (Riso): > 200 kΩ - 1 MΩ