LG · 17 Verified Diagnostic Sheets
ESENDEFRIT
Air Conditioning

LG Error Codes: Complete List (17 Faults), Causes & Reset

Complete technical directory of all 17 LG error codes (Air Conditioning) with exact meanings, multimeter reference specs, and reset instructions.

Error Code Technical Meaning Multimeter Specs
LG CH01Indoor ambient temperature sensor (Air probe) open/shortLG ambient probe at 25°C: 10 kΩ (Pipe probe: 5 kΩ)
LG CH05Communication failure between indoor and outdoor unit (5 flashes)LG communication (2-3): 0V to 35V DC oscillating
LG CH21DC Peak Overcurrent on Compressor IPM ModuleResistance between U-V-W compressor phases: ~1.2 Ω
LG CH38Lack of refrigerant gas (Low pressure / No thermal change)Working pressure R32 when cold: 8.0 - 9.0 bar
LG dEDoor open or door lock fault (dE1 / dE2)LG Door Locks (3 or 4 pin): ~1 kΩ on PTC heater
LG dEDryer door open or latch not engagedDoor switch: Closed (0 Ω) with door closed
LG Er CFCondenser fan failure (Lower rear part next to the compressor)Condenser fan: 12V DC dust-free
LG Er dHFailure in the No Frost defrost system (Defrost Heater Error - Does not rise above 8°C in defrost)LG defrost resistance: 180 Ω - 260 Ω | Thermal fuse: 0 Ω (continuity)
LG Er FFFreezer fan failure or ice blockage (Freeze Fan Error)LG freezer fan motor (3 wires): 12V DC (Powered between Red-Black, Signal in Yellow)
LG Er IFIce Maker Fan ErrorFrost Free Ice Maker Fan
LG FEWater overflow (Excessive water level in the tank)LG electronic pressure switch (3 pins): ~22-26 kHz no-load
LG IEWater inlet error (Not reaching the level in 8 minutes)LG solenoid valve coils: 3.8 kΩ to 4.5 kΩ each way
LG LEDirect Drive motor blocked or Hall sensor failure (Rotor/Stator)LG Hall Sensor (6501KW2001A/2002A): ~10 kΩ between extreme pins | Stator: 5-15 Ω between the 3 phases
LG OEDrain error: Does not empty water from drum within 10 minutesLG drain pump resistance: 160 Ω - 200 Ω
LG OECondensate pump blocked or water tank full (Drain Error)LG condensate pump: 230V AC / 12V DC depending on series
LG tEAnomaly in the water temperature sensor (NTC thermistor)LG washing machine NTC probe at 25°C: ~45 kΩ - 50 kΩ
LG UELoad imbalance during spinning (Unbalance Error)Required leg leveling and balanced load