Fault code CH21 on LG units (Dual Inverter, ArtCool, Confort, Therma V, Multi V) indicates: DC Peak Overcurrent on Compressor IPM Module. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Air Conditioning subsystem falls outside factory tolerances.
1. Technical Specifications & Multimeter Values (LG CH21)
| Manufacturer / Brand | LG |
|---|---|
| Error Code | CH21 |
| System / Category | Air Conditioning |
| Compatible Models | Dual Inverter, ArtCool, Confort, Therma V, Multi V |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | Resistance between U-V-W compressor phases: ~1.2 Ω |
2. Guided Symptom Troubleshooting Matrix
🔎 Does CH21 jump just at the moment when the outdoor unit tries to start the compressor?
✓ Scenario A: Yes (Confirmed)
Compressor blocked or external board IPM module shorted. Measure IPM diodes with the multimeter.
✕ Scenario B: No (Not Present)
Mains voltage too low (< 195V) when starting.
3. Step-by-Step Multimeter Testing Procedure (CH21)
- Safety Power Isolation: Disconnect the LG unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault CH21 for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Resistance between U-V-W compressor phases: ~1.2 Ω.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear LG Error CH21
🔄 LG CH21 Reset: Cut power for 5 minutes.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?
Check OEM & aftermarket availability for LG Replacement Sensor / Part:
Want to use the interactive diagnostic wizard or electrical calculators for LG CH21?
⚡ Open in Interactive Simulator →
⚡ Open in Interactive Simulator →
5. Frequently Asked Questions: LG Error Code CH21
What does LG error code CH21 mean?
LG CH21: DC Peak Overcurrent on Compressor IPM Module (Dual Inverter, ArtCool, Confort, Therma V, Multi V). Multimeter Specs: Resistance between U-V-W compressor phases: ~1.2 Ω.
How do I reset LG fault code CH21?
Cut power for 5 minutes.
What multimeter values should I check for LG code CH21?
Resistance between U-V-W compressor phases: ~1.2 Ω