LG Error Code CH01: Meaning, Multimeter Diagnosis & Fix
Fault code CH01 on LG units (Dual Inverter, ArtCool, Confort, Therma V, Multi V) indicates: Indoor ambient temperature sensor (Air probe) open/short. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Air Conditioning subsystem falls outside factory tolerances.
1. Technical Specifications & Multimeter Values (LG CH01)
| Manufacturer / Brand | LG |
|---|---|
| Error Code | CH01 |
| System / Category | Air Conditioning |
| Compatible Models | Dual Inverter, ArtCool, Confort, Therma V, Multi V |
| Severity Level | Low Severity · Maintenance Advisory |
| Multimeter Specs | LG ambient probe at 25°C: 10 kΩ (Pipe probe: 5 kΩ) |
2. Guided Symptom Troubleshooting Matrix
🔎 Does CH01 come out as soon as you turn on the split?
✓ Scenario A: Yes (Confirmed)
The black probe in front of the internal battery has become loose from the connector or is cut.
✕ Scenario B: No (Not Present)
Replace interior ambient probe.
3. Step-by-Step Multimeter Testing Procedure (CH01)
- Safety Power Isolation: Disconnect the LG unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault CH01 for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: LG ambient probe at 25°C: 10 kΩ (Pipe probe: 5 kΩ).
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear LG Error CH01
🔄 LG CH01 Reset: Automatic reset when connecting probe.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?
Check OEM & aftermarket availability for LG Replacement Sensor / Part:
Want to use the interactive diagnostic wizard or electrical calculators for LG CH01?
⚡ Open in Interactive Simulator →
⚡ Open in Interactive Simulator →
5. Frequently Asked Questions: LG Error Code CH01
What does LG error code CH01 mean?
LG CH01: Indoor ambient temperature sensor (Air probe) open/short (Dual Inverter, ArtCool, Confort, Therma V, Multi V). Multimeter Specs: LG ambient probe at 25°C: 10 kΩ (Pipe probe: 5 kΩ).
How do I reset LG fault code CH01?
Automatic reset when connecting probe.
What multimeter values should I check for LG code CH01?
LG ambient probe at 25°C: 10 kΩ (Pipe probe: 5 kΩ)