Kosner / Giatsu / Mundoclima / Johnson Β· 3 Verified Diagnostic Sheets
ESENDEFRIT
Air Conditioning

Kosner / Giatsu / Mundoclima / Johnson Error Codes: Complete List (3 Faults), Causes & Reset

Complete technical directory of all 3 Kosner / Giatsu / Mundoclima / Johnson error codes (Air Conditioning) with exact meanings, multimeter reference specs, and reset instructions.

Error Code Technical Meaning Multimeter Specs
Kosner / Giatsu / Mundoclima / Johnson E1 / E5Communication error between indoor unit and outdoor unit ('S' signal wire cut or outdoor panel without power)Communication voltage between terminals N and S: Oscillating 0V ↔ 24V/50V DC
Kosner / Giatsu / Mundoclima / Johnson EC / EL 0CDetection of refrigerant gas leak or lack of cooling in the evaporator after 10 minutes of operation (Refrigerant Leakage Detection)Internal battery (T2) and ambient (T1) probe at 25°C: 10 kΞ©
Kosner / Giatsu / Mundoclima / Johnson P0 / P4Protection against overcurrent of the IPM module or start failure of the Inverter compressor (Error P0 or P4)Inverter U-V-W compressor winding resistance: 0.9 Ξ© to 2.2 Ξ© balanced
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Kosner Replacement Sensor / Part:

Other Manufacturers & Fault Code Directories