Kosner / Giatsu / Mundoclima / Johnson Error Code E1 / E5: Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Kosner / Giatsu / Mundoclima / Johnson E1 / E5)
| Manufacturer / Brand | Kosner / Giatsu / Mundoclima / Johnson |
|---|---|
| Error Code | E1 / E5 |
| System / Category | Air Conditioning |
| Compatible Models | Splits and Ducted Kosner (Nova, Gold), Giatsu (Aroma 2, GIA), Mundoclima (MUPR-H) and Johnson (Everest, JDM) |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | Communication voltage between terminals N and S: Oscillating 0V β 24V/50V DC |
2. Guided Symptom Troubleshooting Matrix
The interior panel does not receive a response through the **communication cable ('S' or 'W')**: 1) Cut off the air conditioning circuit breaker in the electrical panel for **5 full minutes** (the capacitors on the exterior panel take 3 minutes to discharge and reset the microprocessor). 2) If E1 still comes out when the light goes up, open the terminal cover of the outdoor unit and check the **20A/25A ceramic fuse** and the rectifier bridge of the inverter board.
Measure between the **N (Neutral) and S (Signal)** terminal with the multimeter in DC: the voltage has to dance up and down between **0V and 24V-50V DC**; if it is fixed at 0V, the outer plate is dead.
3. Step-by-Step Multimeter Testing Procedure (E1 / E5)
- Safety Power Isolation: Disconnect the Kosner / Giatsu / Mundoclima / Johnson unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault E1 / E5 for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Communication voltage between terminals N and S: Oscillating 0V β 24V/50V DC.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Kosner / Giatsu / Mundoclima / Johnson Error E1 / E5
Check OEM & aftermarket availability for Kosner Replacement Sensor / Part:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Kosner / Giatsu / Mundoclima / Johnson Error Code E1 / E5
What does Kosner / Giatsu / Mundoclima / Johnson error code E1 / E5 mean?
Kosner / Giatsu / Mundoclima / Johnson E1 / E5: Communication error between indoor unit and outdoor unit ('S' signal wire cut or outdoor panel without power) (Splits and Ducted Kosner (Nova, Gold), Giatsu (Aroma 2, GIA), Mundoclima (MUPR-H) and Johnson (Everest, JDM)). Multimeter Specs: Communication voltage between terminals N and S: Oscillating 0V β 24V/50V DC.
How do I reset Kosner / Giatsu / Mundoclima / Johnson fault code E1 / E5?
Lower the circuit breaker of the electrical panel for 5 minutes to discharge the external inverter board.
What multimeter values should I check for Kosner / Giatsu / Mundoclima / Johnson code E1 / E5?
Communication voltage between terminals N and S: Oscillating 0V β 24V/50V DC