Dixell / Eliwell Error Codes: Complete List (3 Faults), Causes & Reset

Complete technical directory of all 3 Dixell / Eliwell error codes (Commercial Refrigeration & Catering) with exact meanings, multimeter reference specs, and reset instructions.

Error Code Technical Meaning Multimeter Specs
Dixell / Eliwell HAAlarm of maximum temperature exceeded in the cold room (High Temperature Alarm - Equivalent to AH)Commercial compressor consumption 1/3 HP: ~2.2 A | Dust-free condenser
Dixell / Eliwell P1Failure in the chamber temperature probe (Ambient probe open or short circuit - Equivalent to E1 in Eliwell)Dixell/Eliwell NTC probe at 25°C: 10 kΩ (at 0°C: ~32.6 kΩ) | If it is a PTC probe at 25°C: ~990 Ω (Do not mix NTC with PTC!)
Dixell / Eliwell P2Failure in the evaporator defrost end probe (Equivalent to E2 in Eliwell)NTC evaporator probe at 25°C: 10 kΩ (at -10°C: ~55 kΩ)