Dixell / Eliwell Error Code P1: Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Dixell / Eliwell P1)
| Manufacturer / Brand | Dixell / Eliwell |
|---|---|
| Error Code | P1 |
| System / Category | Commercial Refrigeration & Catering |
| Compatible Models | Termostatos Digitales Cold Storage Rooms, Botelleros and Mesas Frías (XR20CX, XR60CX, ID974) |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | Dixell/Eliwell NTC probe at 25°C: 10 kΩ (at 0°C: ~32.6 kΩ) | If it is a PTC probe at 25°C: ~990 Ω (Do not mix NTC with PTC!) |
2. Guided Symptom Troubleshooting Matrix
The NTC probe that measures the cold inside the furniture has broken (cable caught in a tray) or moisture has entered the metal capsule. While P1 is output, the compressor works in emergency mode for periods of time (e.g. 10 min on / 10 min off) to avoid damaging the material.
Open the Dixell thermostat box, remove the probe from the probe terminals 1 and insert a new NTC/PTC probe of the same type.
3. Step-by-Step Multimeter Testing Procedure (P1)
- Safety Power Isolation: Disconnect the Dixell / Eliwell unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault P1 for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Dixell/Eliwell NTC probe at 25°C: 10 kΩ (at 0°C: ~32.6 kΩ) | If it is a PTC probe at 25°C: ~990 Ω (Do not mix NTC with PTC!).
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Dixell / Eliwell Error P1
Check OEM & aftermarket availability for Dixell NTC Temperature Sensor:
⚡ Open in Interactive Simulator →
5. Frequently Asked Questions: Dixell / Eliwell Error Code P1
What does Dixell / Eliwell error code P1 mean?
Dixell / Eliwell P1: Failure in the chamber temperature probe (Ambient probe open or short circuit - Equivalent to E1 in Eliwell) (Termostatos Digitales Cold Storage Rooms, Botelleros and Mesas Frías (XR20CX, XR60CX, ID974)). Multimeter Specs: Dixell/Eliwell NTC probe at 25°C: 10 kΩ (at 0°C: ~32.6 kΩ) | If it is a PTC probe at 25°C: ~990 Ω (Do not mix NTC with PTC!).
How do I reset Dixell / Eliwell fault code P1?
It disappears instantly when you connect a new probe to the two screws of 'Probe 1'.
What multimeter values should I check for Dixell / Eliwell code P1?
Dixell/Eliwell NTC probe at 25°C: 10 kΩ (at 0°C: ~32.6 kΩ) | If it is a PTC probe at 25°C: ~990 Ω (Do not mix NTC with PTC!)