Bronpi Β· 2 Verified Diagnostic Sheets
ESENDEFRIT
Boilers & Heating

Bronpi Error Codes: Complete List (2 Faults), Causes & Reset

Complete technical directory of all 2 Bronpi error codes (Boilers & Heating) with exact meanings, multimeter reference specs, and reset instructions.

Error Code Technical Meaning Multimeter Specs
Bronpi Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos)The Bronpi pellet stove turns off displaying 'Er02' or 'AL 02' (Lack of depression in the combustion chamber / Obstructed draft)The smoke differential pressure switch requires a minimum depression of > 10 - 15 Pascals created by the smoke extractor.
Bronpi Er05 / AL 05 / A01 (ignition failure lockout - No Prende Flame)The Bronpi pellet stove puts pellets into the basket but no fire comes out and it beeps with the code 'Er05' or 'AL 05' (No Light-in)Bronpi 230V (280W - 320W) ignition plug resistance: ~165 Ξ© to 190 Ξ© (If you measure infinite OL on the multimeter, it is blown)