Bronpi Error Code Er05 / AL 05 / A01 (ignition failure lockout - No Prende Flame): Meaning, Multimeter Diagnosis & Fix

Fault code Er05 / AL 05 / A01 (ignition failure lockout - No Prende Flame) on Bronpi units (Estufas, Insertables, Termoestufas and Boilers of Pellets Bronpi (Noa, Dora, Abril, Clara, Alpes, Neva, Hydro)) indicates: The Bronpi pellet stove puts pellets into the basket but no fire comes out and it beeps with the code 'Er05' or 'AL 05' (No Light-in). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Bronpi Er05 / AL 05 / A01 (ignition failure lockout - No Prende Flame))

Manufacturer / BrandBronpi
Error CodeEr05 / AL 05 / A01 (ignition failure lockout - No Prende Flame)
System / CategoryBoilers & Heating
Compatible ModelsEstufas, Insertables, Termoestufas and Boilers of Pellets Bronpi (Noa, Dora, Abril, Clara, Alpes, Neva, Hydro)
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsBronpi 230V (280W - 320W) ignition plug resistance: ~165 Ω to 190 Ω (If you measure infinite OL on the multimeter, it is blown)

2. Guided Symptom Troubleshooting Matrix

🔎 Does your Bronpi stove fill the brazier with pellets, does white smoke come out or is it completely cold and after 15 minutes it beeps saying 'Ignition Failure (Er05 / AL05)'?
✓ Scenario A: Yes (Confirmed)

If the basket (burner) is full of unburned pellets: **SAFETY IMPORTANT!**: **ALWAYS empty all the raw pellets accumulated in the basket by hand or with a vacuum cleaner before pressing the start button again** (if you try to turn on with a double accumulated load, it will cause an explosion of white smoke inside the room). • **If the pellets in the basket are cold and no smoke comes out**: the **Ignition Resistor (Steel or quartz glow plug, 250W - 350W)** that is inserted in the tube behind the basket has melted. It is the number 1 wearing part of all pellet stoves (~€16 on Amazon and can be changed from the back by removing 1 screw or unscrewing it). • **If smoke and spark do come out but it takes a long time**: when placing the iron basket after cleaning it, you have not made its rear hole coincide with the resistance tube.

✕ Scenario B: No (Not Present)

**How ​​to clear the alarm on the Bronpi remote**: Press and hold the **On / Off button for 3 to 5 seconds** until it beeps and goes to *'Final Cleaning / Off'*.

3. Step-by-Step Multimeter Testing Procedure (Er05 / AL 05 / A01 (ignition failure lockout - No Prende Flame))

  1. Safety Power Isolation: Disconnect the Bronpi unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Er05 / AL 05 / A01 (ignition failure lockout - No Prende Flame) for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Bronpi 230V (280W - 320W) ignition plug resistance: ~165 Ω to 190 Ω (If you measure infinite OL on the multimeter, it is blown).
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Bronpi Error Er05 / AL 05 / A01 (ignition failure lockout - No Prende Flame)

🔄 Bronpi Er05 / AL 05 / A01 (ignition failure lockout - No Prende Flame) Reset: Completely empty the unburned pellets from the brazier, press and hold the Power button for 4 seconds to clear the alarm and replace the spark plug resistance if it does not heat up.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (Ignition & Flame Electrode)?

Check OEM & aftermarket availability for Bronpi Ignition & Flame Electrode:

Want to use the interactive diagnostic wizard or electrical calculators for Bronpi Er05 / AL 05 / A01 (ignition failure lockout - No Prende Flame)?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Bronpi Error Code Er05 / AL 05 / A01 (ignition failure lockout - No Prende Flame)

What does Bronpi error code Er05 / AL 05 / A01 (ignition failure lockout - No Prende Flame) mean?

Bronpi Er05 / AL 05 / A01 (ignition failure lockout - No Prende Flame): The Bronpi pellet stove puts pellets into the basket but no fire comes out and it beeps with the code 'Er05' or 'AL 05' (No Light-in) (Estufas, Insertables, Termoestufas and Boilers of Pellets Bronpi (Noa, Dora, Abril, Clara, Alpes, Neva, Hydro)). Multimeter Specs: Bronpi 230V (280W - 320W) ignition plug resistance: ~165 Ω to 190 Ω (If you measure infinite OL on the multimeter, it is blown).

How do I reset Bronpi fault code Er05 / AL 05 / A01 (ignition failure lockout - No Prende Flame)?

Completely empty the unburned pellets from the brazier, press and hold the Power button for 4 seconds to clear the alarm and replace the spark plug resistance if it does not heat up.

What multimeter values should I check for Bronpi code Er05 / AL 05 / A01 (ignition failure lockout - No Prende Flame)?

Bronpi 230V (280W - 320W) ignition plug resistance: ~165 Ω to 190 Ω (If you measure infinite OL on the multimeter, it is blown)