Bronpi Error Code Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos): Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Bronpi Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos))
| Manufacturer / Brand | Bronpi |
|---|---|
| Error Code | Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos) |
| System / Category | Boilers & Heating |
| Compatible Models | Estufas, Insertables, Termoestufas and Boilers of Pellets Bronpi (Noa, Dora, Abril, Clara, Alpes, Neva, Hydro) |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | The smoke differential pressure switch requires a minimum depression of > 10 - 15 Pascals created by the smoke extractor. |
2. Guided Symptom Troubleshooting Matrix
**Er02** means that the **Smoke Pressure Switch** detects that the gases are not coming out properly through the chimney: 1) **The glass door is not closed properly** or the black fiberglass cord on the door is crushed and false air enters. 2) **The rear registration 'T' of the 80mm flue pipe is filled to the top with fine ash**: remove the bottom plug of the rear 'T' with a bag underneath and empty it (if the 'T' is filled with ash, plug the pipe and skip Er02). 3) Blow through the transparent silicone tube that goes to the internal round pressure switch to remove possible soot.
Empty the lower plug of the 'T' of the rear smoke outlet pipe and clean the exchanger chamber.
3. Step-by-Step Multimeter Testing Procedure (Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos))
- Safety Power Isolation: Disconnect the Bronpi unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos) for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: The smoke differential pressure switch requires a minimum depression of > 10 - 15 Pascals created by the smoke extractor..
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Bronpi Error Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos)
Check OEM & aftermarket availability for Bronpi Pressure Switch:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Bronpi Error Code Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos)
What does Bronpi error code Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos) mean?
Bronpi Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos): The Bronpi pellet stove turns off displaying 'Er02' or 'AL 02' (Lack of depression in the combustion chamber / Obstructed draft) (Estufas, Insertables, Termoestufas and Boilers of Pellets Bronpi (Noa, Dora, Abril, Clara, Alpes, Neva, Hydro)). Multimeter Specs: The smoke differential pressure switch requires a minimum depression of > 10 - 15 Pascals created by the smoke extractor..
How do I reset Bronpi fault code Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos)?
Remove and empty the ash from the manhole cover on the rear 'T' of the chimney, close the door firmly and hold down Power for 4 seconds.
What multimeter values should I check for Bronpi code Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos)?
The smoke differential pressure switch requires a minimum depression of > 10 - 15 Pascals created by the smoke extractor.