Boilers & Heating High Severity · Safety Lockout

Bronpi Error Code Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos): Meaning, Multimeter Diagnosis & Fix

Fault code Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos) on Bronpi units (Estufas, Insertables, Termoestufas and Boilers of Pellets Bronpi (Noa, Dora, Abril, Clara, Alpes, Neva, Hydro)) indicates: The Bronpi pellet stove turns off displaying 'Er02' or 'AL 02' (Lack of depression in the combustion chamber / Obstructed draft). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Bronpi Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos))

Manufacturer / BrandBronpi
Error CodeEr02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos)
System / CategoryBoilers & Heating
Compatible ModelsEstufas, Insertables, Termoestufas and Boilers of Pellets Bronpi (Noa, Dora, Abril, Clara, Alpes, Neva, Hydro)
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsThe smoke differential pressure switch requires a minimum depression of > 10 - 15 Pascals created by the smoke extractor.

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does your Bronpi stove beep the minute it starts or on windy days with the code Er02 / AL02?
βœ“ Scenario A: Yes (Confirmed)

**Er02** means that the **Smoke Pressure Switch** detects that the gases are not coming out properly through the chimney: 1) **The glass door is not closed properly** or the black fiberglass cord on the door is crushed and false air enters. 2) **The rear registration 'T' of the 80mm flue pipe is filled to the top with fine ash**: remove the bottom plug of the rear 'T' with a bag underneath and empty it (if the 'T' is filled with ash, plug the pipe and skip Er02). 3) Blow through the transparent silicone tube that goes to the internal round pressure switch to remove possible soot.

βœ• Scenario B: No (Not Present)

Empty the lower plug of the 'T' of the rear smoke outlet pipe and clean the exchanger chamber.

3. Step-by-Step Multimeter Testing Procedure (Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos))

  1. Safety Power Isolation: Disconnect the Bronpi unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos) for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: The smoke differential pressure switch requires a minimum depression of > 10 - 15 Pascals created by the smoke extractor..
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Bronpi Error Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos)

πŸ”„ Bronpi Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos) Reset: Remove and empty the ash from the manhole cover on the rear 'T' of the chimney, close the door firmly and hold down Power for 4 seconds.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Pressure Switch)?

Check OEM & aftermarket availability for Bronpi Pressure Switch:

Want to use the interactive diagnostic wizard or electrical calculators for Bronpi Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos)?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Bronpi Error Code Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos)

What does Bronpi error code Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos) mean?

Bronpi Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos): The Bronpi pellet stove turns off displaying 'Er02' or 'AL 02' (Lack of depression in the combustion chamber / Obstructed draft) (Estufas, Insertables, Termoestufas and Boilers of Pellets Bronpi (Noa, Dora, Abril, Clara, Alpes, Neva, Hydro)). Multimeter Specs: The smoke differential pressure switch requires a minimum depression of > 10 - 15 Pascals created by the smoke extractor..

How do I reset Bronpi fault code Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos)?

Remove and empty the ash from the manhole cover on the rear 'T' of the chimney, close the door firmly and hold down Power for 4 seconds.

What multimeter values should I check for Bronpi code Er02 / AL 02 / Er12 (Fault / Failure pressure switch / Depresión Humos)?

The smoke differential pressure switch requires a minimum depression of > 10 - 15 Pascals created by the smoke extractor.