Beretta Β· 5 Verified Diagnostic Sheets
ESENDEFRIT
Boilers & Heating

Beretta Error Codes: Complete List (5 Faults), Causes & Reset

Complete technical directory of all 5 Beretta error codes (Boilers & Heating) with exact meanings, multimeter reference specs, and reset instructions.

Error Code Technical Meaning Multimeter Specs
Beretta A01Lockout due to lack of flame (steady red light or code A01 on screen)Ionization > 1.5 µA
Beretta A01 / Rojo FijoBlockage due to lack of flame in the burner (Ignition or ionization electrode failure)NTC Beretta probe at 25°C: 10 kΞ© | Ignition/ionization electrode 3-4 mm from the burner
Beretta A02 / A03Intervention of the overtemperature limit thermostat (A02) or failure of the smoke/fan pressure switch (A03)Limit safety thermostat: 0 Ξ© cold closed | Smoke pressure switch: 0 Ξ© closed with extractor on
Beretta A04Insufficient water pressure in the heating circuit (Error 40)Closed pressure switch contact > 0.6 bar
Beretta E40 / 40°C flashes (Ciao)Low water pressure in the Beretta boiler (< 0.6 bar)Correct hydraulic pressure when cold: 1.2 to 1.5 bar
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Beretta Replacement Sensor / Part:

Other Manufacturers & Fault Code Directories