Beretta Error Code A02 / A03: Meaning, Multimeter Diagnosis & Fix

Fault code A02 / A03 on Beretta units (Ciao, Ciao Green, Mynute, Mynute Green, Exclusive, Super Exclusive) indicates: Intervention of the overtemperature limit thermostat (A02) or failure of the smoke/fan pressure switch (A03). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Beretta A02 / A03)

Manufacturer / BrandBeretta
Error CodeA02 / A03
System / CategoryBoilers & Heating
Compatible ModelsCiao, Ciao Green, Mynute, Mynute Green, Exclusive, Super Exclusive
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsLimit safety thermostat: 0 Ω cold closed | Smoke pressure switch: 0 Ω closed with extractor on

2. Guided Symptom Troubleshooting Matrix

🔎 Does the boiler stop with code A02 or A03?
✓ Scenario A: Yes (Confirmed)

**For A02**: overheating (> 95°C) because the circulator pump is stuck or the 3-way valve does not move. **For A03**: the upper smoke pressure switch does not close; Blow out the two silicone tubes that go to the fan and clean the aluminum Venturi.

✕ Scenario B: No (Not Present)

Let it cool for 15 minutes, check the pump/fan and turn the dial to 'R' (Reset) for 5 seconds.

3. Step-by-Step Multimeter Testing Procedure (A02 / A03)

  1. Safety Power Isolation: Disconnect the Beretta unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault A02 / A03 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Limit safety thermostat: 0 Ω cold closed | Smoke pressure switch: 0 Ω closed with extractor on.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Beretta Error A02 / A03

🔄 Beretta A02 / A03 Reset: Place the selector in the 'R / Off' position for 5 seconds and return it to service mode.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (Pressure Switch)?

Check OEM & aftermarket availability for Beretta Pressure Switch:

Want to use the interactive diagnostic wizard or electrical calculators for Beretta A02 / A03?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Beretta Error Code A02 / A03

What does Beretta error code A02 / A03 mean?

Beretta A02 / A03: Intervention of the overtemperature limit thermostat (A02) or failure of the smoke/fan pressure switch (A03) (Ciao, Ciao Green, Mynute, Mynute Green, Exclusive, Super Exclusive). Multimeter Specs: Limit safety thermostat: 0 Ω cold closed | Smoke pressure switch: 0 Ω closed with extractor on.

How do I reset Beretta fault code A02 / A03?

Place the selector in the 'R / Off' position for 5 seconds and return it to service mode.

What multimeter values should I check for Beretta code A02 / A03?

Limit safety thermostat: 0 Ω cold closed | Smoke pressure switch: 0 Ω closed with extractor on