Beretta Error Code A01 / Rojo Fijo: Meaning, Multimeter Diagnosis & Fix

Fault code A01 / Rojo Fijo on Beretta units (Ciao, Ciao Green, Mynute, Mynute Green, Exclusive, Super Exclusive) indicates: Blockage due to lack of flame in the burner (Ignition or ionization electrode failure). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Beretta A01 / Rojo Fijo)

Manufacturer / BrandBeretta
Error CodeA01 / Rojo Fijo
System / CategoryBoilers & Heating
Compatible ModelsCiao, Ciao Green, Mynute, Mynute Green, Exclusive, Super Exclusive
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsNTC Beretta probe at 25°C: 10 kΩ | Ignition/ionization electrode 3-4 mm from the burner

2. Guided Symptom Troubleshooting Matrix

🔎 Does your Beretta boiler show 'A01' on the display (or steady red light on the Beretta Ciao without display)?
✓ Scenario A: Yes (Confirmed)

No flame detected after 3 ignition attempts: check that the yellow gas cock is open and the counter has not tripped. In Beretta Ciao and Mynute that are several years old, the **gas valve relay soldered on the electronic board** fails when cold (if you tap the control panel lightly when starting and it turns on, it is the board relay).

✕ Scenario B: No (Not Present)

On Beretta condensation models, check that the drain trap is not clogged and filled with water up to the burner.

3. Step-by-Step Multimeter Testing Procedure (A01 / Rojo Fijo)

  1. Safety Power Isolation: Disconnect the Beretta unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault A01 / Rojo Fijo for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: NTC Beretta probe at 25°C: 10 kΩ | Ignition/ionization electrode 3-4 mm from the burner.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Beretta Error A01 / Rojo Fijo

🔄 Beretta A01 / Rojo Fijo Reset: Turn the main selector to the '0 / Off / R' position for 5 seconds and return it to the Winter or Summer position.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (NTC Temperature Sensor)?

Check OEM & aftermarket availability for Beretta NTC Temperature Sensor:

Want to use the interactive diagnostic wizard or electrical calculators for Beretta A01 / Rojo Fijo?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Beretta Error Code A01 / Rojo Fijo

What does Beretta error code A01 / Rojo Fijo mean?

Beretta A01 / Rojo Fijo: Blockage due to lack of flame in the burner (Ignition or ionization electrode failure) (Ciao, Ciao Green, Mynute, Mynute Green, Exclusive, Super Exclusive). Multimeter Specs: NTC Beretta probe at 25°C: 10 kΩ | Ignition/ionization electrode 3-4 mm from the burner.

How do I reset Beretta fault code A01 / Rojo Fijo?

Turn the main selector to the '0 / Off / R' position for 5 seconds and return it to the Winter or Summer position.

What multimeter values should I check for Beretta code A01 / Rojo Fijo?

NTC Beretta probe at 25°C: 10 kΩ | Ignition/ionization electrode 3-4 mm from the burner