Error Code Technical Meaning Multimeter Specs
Viessmann F2Temperature limiter triggered by overheatingViessmann NTC boiler probe at 25°C: 10 kΩ
Viessmann F2 / F02Disparo of the limitador of temperature of seguridad STB (> 95°C) due to falta of circulación of Water (Error F2)NTC thermistor probe of Boiler Viessmann a 25°C: 10 kΩ
Viessmann F3Flame signal already existing when starting the burnerElectrode insulation > 10 MΩ
Viessmann F4The burner goes into lockout: There is no flame signal (EE / F4)Vitodens ionization current: > 4 µA
Viessmann F4 / F04ignition failure lockout: El burner entra in Lockout / Blockage due to ausencia of Signal of Flame (Error F4 in Viessmann Vitodens)Current of Ionization Minimum Viessmann Vitodens: > 4 µA | Separación electrodos: 3.5 a 4.0 mm