Viessmann Error Code F2: Meaning, Multimeter Diagnosis & Fix

Fault code F2 on Viessmann units (Vitodens 050-W, Vitodens 100-W, Vitodens 200-W) indicates: Temperature limiter triggered by overheating. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Viessmann F2)

Manufacturer / BrandViessmann
Error CodeF2
System / CategoryBoilers & Heating
Compatible ModelsVitodens 050-W, Vitodens 100-W, Vitodens 200-W
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsViessmann NTC boiler probe at 25°C: 10 kΩ

2. Guided Symptom Troubleshooting Matrix

🔎 Does the circulation pump work when starting?
✓ Scenario A: Yes (Confirmed)

Unblock the circulator pump or open the radiator valves.

✕ Scenario B: No (Not Present)

Fixed thermal limiter open in the body of the Inox-Radial exchanger.

3. Step-by-Step Multimeter Testing Procedure (F2)

  1. Safety Power Isolation: Disconnect the Viessmann unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault F2 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Viessmann NTC boiler probe at 25°C: 10 kΩ.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Viessmann Error F2

🔄 Viessmann F2 Reset: Let the thermal block cool and press Reset.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (NTC Temperature Sensor)?

Check OEM & aftermarket availability for Viessmann NTC Temperature Sensor:

Want to use the interactive diagnostic wizard or electrical calculators for Viessmann F2?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Viessmann Error Code F2

What does Viessmann error code F2 mean?

Viessmann F2: Temperature limiter triggered by overheating (Vitodens 050-W, Vitodens 100-W, Vitodens 200-W). Multimeter Specs: Viessmann NTC boiler probe at 25°C: 10 kΩ.

How do I reset Viessmann fault code F2?

Let the thermal block cool and press Reset.

What multimeter values should I check for Viessmann code F2?

Viessmann NTC boiler probe at 25°C: 10 kΩ