Victron Energy Error Code Error #38 / #39: Meaning, Multimeter Diagnosis & Fix

Fault code Error #38 / #39 on Victron Energy units (Inverters/Cargadores MultiPlus-II, Quattro, Reguladores SmartSolar MPPT) indicates: Photovoltaic input shutdown due to battery overvoltage or sudden BMS cutoff (SmartSolar MPPT Regulators). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Solar Inverters & Water Heaters subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Victron Energy Error #38 / #39)

Manufacturer / BrandVictron Energy
Error CodeError #38 / #39
System / CategorySolar Inverters & Water Heaters
Compatible ModelsInverters/Cargadores MultiPlus-II, Quattro, Reguladores SmartSolar MPPT
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsMandatory MPPT connection sequence: 1st Battery (to detect 12/24/48V) -> 2nd Solar Panels

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does the VictronConnect app display Error #38 (Input shutdown due to excessive battery voltage)?
βœ“ Scenario A: Yes (Confirmed)

The BMS of the lithium battery has suddenly cut off charging per full cell while the MPPT regulator was drawing many amperes of sun, causing a voltage spike that blocks the MPPT for protection.

βœ• Scenario B: No (Not Present)

Disconnect the solar panels from the MPPT first, then disconnect the battery from the MPPT for 2 minutes; Reconnect **1st the Battery** and **2nd the Panels**.

3. Step-by-Step Multimeter Testing Procedure (Error #38 / #39)

  1. Safety Power Isolation: Disconnect the Victron Energy unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Error #38 / #39 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Mandatory MPPT connection sequence: 1st Battery (to detect 12/24/48V) -> 2nd Solar Panels.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Victron Energy Error Error #38 / #39

πŸ”„ Victron Energy Error #38 / #39 Reset: Reset the MPPT regulator by disconnecting panels and battery (always connect the battery first).
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Victron Energy Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Victron Energy Error #38 / #39?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Victron Energy Error Code Error #38 / #39

What does Victron Energy error code Error #38 / #39 mean?

Victron Energy Error #38 / #39: Photovoltaic input shutdown due to battery overvoltage or sudden BMS cutoff (SmartSolar MPPT Regulators) (Inverters/Cargadores MultiPlus-II, Quattro, Reguladores SmartSolar MPPT). Multimeter Specs: Mandatory MPPT connection sequence: 1st Battery (to detect 12/24/48V) -> 2nd Solar Panels.

How do I reset Victron Energy fault code Error #38 / #39?

Reset the MPPT regulator by disconnecting panels and battery (always connect the battery first).

What multimeter values should I check for Victron Energy code Error #38 / #39?

Mandatory MPPT connection sequence: 1st Battery (to detect 12/24/48V) -> 2nd Solar Panels