Victron Energy Error Code Error #38 / #39: Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Victron Energy Error #38 / #39)
| Manufacturer / Brand | Victron Energy |
|---|---|
| Error Code | Error #38 / #39 |
| System / Category | Solar Inverters & Water Heaters |
| Compatible Models | Inverters/Cargadores MultiPlus-II, Quattro, Reguladores SmartSolar MPPT |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | Mandatory MPPT connection sequence: 1st Battery (to detect 12/24/48V) -> 2nd Solar Panels |
2. Guided Symptom Troubleshooting Matrix
The BMS of the lithium battery has suddenly cut off charging per full cell while the MPPT regulator was drawing many amperes of sun, causing a voltage spike that blocks the MPPT for protection.
Disconnect the solar panels from the MPPT first, then disconnect the battery from the MPPT for 2 minutes; Reconnect **1st the Battery** and **2nd the Panels**.
3. Step-by-Step Multimeter Testing Procedure (Error #38 / #39)
- Safety Power Isolation: Disconnect the Victron Energy unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault Error #38 / #39 for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Mandatory MPPT connection sequence: 1st Battery (to detect 12/24/48V) -> 2nd Solar Panels.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Victron Energy Error Error #38 / #39
Check OEM & aftermarket availability for Victron Energy Replacement Sensor / Part:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Victron Energy Error Code Error #38 / #39
What does Victron Energy error code Error #38 / #39 mean?
Victron Energy Error #38 / #39: Photovoltaic input shutdown due to battery overvoltage or sudden BMS cutoff (SmartSolar MPPT Regulators) (Inverters/Cargadores MultiPlus-II, Quattro, Reguladores SmartSolar MPPT). Multimeter Specs: Mandatory MPPT connection sequence: 1st Battery (to detect 12/24/48V) -> 2nd Solar Panels.
How do I reset Victron Energy fault code Error #38 / #39?
Reset the MPPT regulator by disconnecting panels and battery (always connect the battery first).
What multimeter values should I check for Victron Energy code Error #38 / #39?
Mandatory MPPT connection sequence: 1st Battery (to detect 12/24/48V) -> 2nd Solar Panels