Vaillant · 16 Verified Diagnostic Sheets
ESENDEFRIT
Boilers & Heating

Vaillant Error Codes: Complete List (16 Faults), Causes & Reset

Complete technical directory of all 16 Vaillant error codes (Boilers & Heating) with exact meanings, multimeter reference specs, and reset instructions.

Error Code Technical Meaning Multimeter Specs
Vaillant F20Safety limit thermostat trip (Overheating > 95°C)Limit thermostat: NC contact (0 Ω when cold, opens at > 95°C)
Vaillant F22Lack of water or insufficient pressure (< 0.3 bar)Optimal pressure: 1.2 - 1.5 bar | Pressure sensor: 5V DC (1.2V signal at 1.5 bar)
Vaillant F23Excessive thermal difference (> 35°C) between flow and returnNTC flow/return probes at 25°C: 10 kΩ (at 50°C: ~3.6 kΩ)
Vaillant F24Subida of temperature demasiado rápida or falta of circulación of WaterGradiente Thermal Maximum: < 45K | NTC sensors a 25°C: 10 kΩ
Vaillant F27Parasitic flame detection (Detects flame with closed valve)Electrode-chassis insulation: > 20 MΩ dry
Vaillant F28Ignition failure lockout (No flame detected)Min ionization: > 1.5 µA | Gas valve coil: 120-180 Ω | Gas pressure: 20 mbar
Vaillant F29Flame loss during operationStable ionization current: 3 to 6 µA | Electrode separation: 3.5 mm
Vaillant F32Anomaly in fan revolutions (Hall Effect)DC fan power: 24V DC | PWM signal: 5V | Hall Tachometer: 5V Pulses
Vaillant F49voltage drop in el communication bus eBUS (short circuit or overload in Thermostat)voltage nominal bus eBUS Vaillant: 15V a 24V DC (Polarity independent)
Vaillant F519Cut-off due to low pressure in the refrigeration circuitaroTHERM Plus Refrigerant: R290 (High Efficiency Propane)
Vaillant F54pressure of suministro of gas insuficiente or Fault / Failure in pressure switch of gaspressure entrada Gas Natural: 17 a 25 mbar | GLP Butano/Propano: 28 a 37 mbar
Vaillant F61Gas valve governance failure from the board (PCB)Gas valve stepper motor resistance: ~85 Ω per winding
Vaillant F62Excessive delay in closing the gas valveMaximum valve closing time: < 1.5 s | Leak tightness: 0 mbar
Vaillant F75Does not detect pressure jump (+0.2 bar) when starting the pumpRequired differential jump: >= 200 mbar in 5 seconds
Vaillant F752Insufficient water flow in the hydraulic circuit (Flow anomaly)Minimum aroTHERM flow rate: > 540 l/h - 700 l/h depending on power
Vaillant F83Insufficient temperature rise in las NTC sensors when igniting the burnerMinimum required differential at startup: > 2°C in 20 seconds