Saunier Duval Β· 10 Verified Diagnostic Sheets
ESENDEFRIT
Boilers & Heating

Saunier Duval Error Codes: Complete List (10 Faults), Causes & Reset

Complete technical directory of all 10 Saunier Duval error codes (Boilers & Heating) with exact meanings, multimeter reference specs, and reset instructions.

Error Code Technical Meaning Multimeter Specs
Saunier Duval F1Loss of flame or lack of ignition (ThemaClassic Models)Inlet gas pressure: 20 mbar Natural Gas
Saunier Duval F11Fault / Failure of communication between the Board / Plate principal and la interfaz of display (Sin recepción)Power supply bus display: 5V / 24V DC
Saunier Duval F13Communication failure or short circuit on main board24V DC and 5V DC line on board without short circuits to ground
Saunier Duval F14Delivery temperature greater than 95°C (Electronic control)Saunier NTC probe at 25°C: 10 kΞ©
Saunier Duval F2Smoke extraction failure (Pressure switch / Air flow meter)Extractor resistance: ~65 Ξ©
Saunier Duval F20Incompatibilidad of software between display and Board / Plate base or Fault / Failure of gas solenoid valveConfiguración EEPROM of modelo requerida
Saunier Duval F28Misfire at startup (No flame)Motorized gas valve: 24V DC | Ionization > 1.5 µA
Saunier Duval F33Anomalía in el air differential pressure switch (No abre at rest (idle) or no cierra in marcha)pressure switch Air: 0 Ξ© closed with Fan in marcha
Saunier Duval F5Overheating: Limit thermostat trip (> 97°C)Klixon overtemperature: 0 Ξ© closed
Saunier Duval F9Water pressure sensor failure (F09)Captor power: 5V DC | Output at 1.5 bar: ~1.2V DC
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Saunier Duval Replacement Sensor / Part:

Other Manufacturers & Fault Code Directories