Saunier Duval Error Code F28: Meaning, Multimeter Diagnosis & Fix

Fault code F28 on Saunier Duval units (Themafast, Themacondens, ThemaClassic, Isofast, Semia) indicates: Misfire at startup (No flame). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Saunier Duval F28)

Manufacturer / BrandSaunier Duval
Error CodeF28
System / CategoryBoilers & Heating
Compatible ModelsThemafast, Themacondens, ThemaClassic, Isofast, Semia
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsMotorized gas valve: 24V DC | Ionization > 1.5 µA

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does water bubble inside before dialing F28?
βœ“ Scenario A: Yes (Confirmed)

Clogged condensate siphon: water floods the burner. Empty and clean the lower siphon glass.

βœ• Scenario B: No (Not Present)

Check open gas cock, gas valve stepper motor or spark electrode.

3. Step-by-Step Multimeter Testing Procedure (F28)

  1. Safety Power Isolation: Disconnect the Saunier Duval unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault F28 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Motorized gas valve: 24V DC | Ionization > 1.5 µA.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Saunier Duval Error F28

πŸ”„ Saunier Duval F28 Reset: Turn off the general button (0/I), wait 10 seconds and turn on.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Saunier Duval Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Saunier Duval F28?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Saunier Duval Error Code F28

What does Saunier Duval error code F28 mean?

Saunier Duval F28: Misfire at startup (No flame) (Themafast, Themacondens, ThemaClassic, Isofast, Semia). Multimeter Specs: Motorized gas valve: 24V DC | Ionization > 1.5 µA.

How do I reset Saunier Duval fault code F28?

Turn off the general button (0/I), wait 10 seconds and turn on.

What multimeter values should I check for Saunier Duval code F28?

Motorized gas valve: 24V DC | Ionization > 1.5 µA