Oven Pizza (Moretti / Cuppone / OEM) Error Code Er1 / Er2 / No Sube of temperature: Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Oven Pizza (Moretti / Cuppone / OEM) Er1 / Er2 / No Sube of temperature)
| Manufacturer / Brand | Oven Pizza (Moretti / Cuppone / OEM) |
|---|---|
| Error Code | Er1 / Er2 / No Sube of temperature |
| System / Category | Commercial Refrigeration & Catering |
| Compatible Models | Hornos of Pizza Electric and of Túnel Moretti Forni, Cuppone, OEM, Zanolli, Pizza Group |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | Pizza oven probe (350°C-450°C): Thermocouple Type J (Iron-Constantan) or Type K (Chromel-Alumel) β Attention: they have + and - polarity! |
2. Guided Symptom Troubleshooting Matrix
1) If it marks **Er1 / Open**: the tip of the **Type J or Type K Thermocouple probe** that appears on the inside side of the chamber has broken (when inserting the metal pizza peel it is very common to hit the tip of the probe and break it). 2) If it heats up but **the refractory floor (the stone) is cold**: there are 3 armored resistances under the refractory stones; With the 400°C heat, the **Faston terminals or copper jumpers on the right side of the oven** are burned and loose, or the bottom **solid state relay (SSR) / contactor** has melted.
Turn off the power to the panel, open the right side connection cover of the oven and visually check which fiberglass cable has a burned terminal.
3. Step-by-Step Multimeter Testing Procedure (Er1 / Er2 / No Sube of temperature)
- Safety Power Isolation: Disconnect the Oven Pizza (Moretti / Cuppone / OEM) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault Er1 / Er2 / No Sube of temperature for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Pizza oven probe (350°C-450°C): Thermocouple Type J (Iron-Constantan) or Type K (Chromel-Alumel) β Attention: they have + and - polarity!.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Oven Pizza (Moretti / Cuppone / OEM) Error Er1 / Er2 / No Sube of temperature
Check OEM & aftermarket availability for Oven Pizza Replacement Sensor / Part:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Oven Pizza (Moretti / Cuppone / OEM) Error Code Er1 / Er2 / No Sube of temperature
What does Oven Pizza (Moretti / Cuppone / OEM) error code Er1 / Er2 / No Sube of temperature mean?
Oven Pizza (Moretti / Cuppone / OEM) Er1 / Er2 / No Sube of temperature: The pizza oven shows a Thermocouple probe error (Er1 / Er2) or heats the ceiling but does not heat the floor stone (Solera) (Hornos of Pizza Electric and of Túnel Moretti Forni, Cuppone, OEM, Zanolli, Pizza Group). Multimeter Specs: Pizza oven probe (350°C-450°C): Thermocouple Type J (Iron-Constantan) or Type K (Chromel-Alumel) β Attention: they have + and - polarity!.
How do I reset Oven Pizza (Moretti / Cuppone / OEM) fault code Er1 / Er2 / No Sube of temperature?
Replace the J/K Thermocouple probe if it marks Er1, or clean the high temperature terminals (stainless steel/nickel) of the hearth resistors.
What multimeter values should I check for Oven Pizza (Moretti / Cuppone / OEM) code Er1 / Er2 / No Sube of temperature?
Pizza oven probe (350°C-450°C): Thermocouple Type J (Iron-Constantan) or Type K (Chromel-Alumel) β Attention: they have + and - polarity!