Fagor / Sammic Error Code E2 / filling: Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Fagor / Sammic E2 / filling)
| Manufacturer / Brand | Fagor / Sammic |
|---|---|
| Error Code | E2 / filling |
| System / Category | Commercial Refrigeration & Catering |
| Compatible Models | Dishwasher and Commercial Bar Glasswashers (Fagor Concept, E-VO, Sammic X-40, X-50) |
| Severity Level | Medium Severity · Protection Mode |
| Multimeter Specs | Minimum hospitality entrance water pressure: 2.0 bar | Grease-free tank level pressure switch |
2. Guided Symptom Troubleshooting Matrix
1) Have you put the **overflow tube (high cylindrical plug)** inside the tank? If you forget to put in the drain pipe after scrubbing the machine, the water goes straight to the drain and the level never rises. 2) Open the wall stopcock and clean the inlet filter.
The transparent tube of the pressure switch (air chamber at the bottom of the tank) is clogged by grease and coffee remains.
3. Step-by-Step Multimeter Testing Procedure (E2 / filling)
- Safety Power Isolation: Disconnect the Fagor / Sammic unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault E2 / filling for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Minimum hospitality entrance water pressure: 2.0 bar | Grease-free tank level pressure switch.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Fagor / Sammic Error E2 / filling
Check OEM & aftermarket availability for Fagor Pressure Switch:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Fagor / Sammic Error Code E2 / filling
What does Fagor / Sammic error code E2 / filling mean?
Fagor / Sammic E2 / filling: Tank filling time exceeded or boiler does not reach level (Fill Timeout) (Dishwasher and Commercial Bar Glasswashers (Fagor Concept, E-VO, Sammic X-40, X-50)). Multimeter Specs: Minimum hospitality entrance water pressure: 2.0 bar | Grease-free tank level pressure switch.
How do I reset Fagor / Sammic fault code E2 / filling?
Place the overflow tube securely in the interior drain, clean the pressure switch air trap and turn it off/on.
What multimeter values should I check for Fagor / Sammic code E2 / filling?
Minimum hospitality entrance water pressure: 2.0 bar | Grease-free tank level pressure switch