Daikin Error Code L5: Meaning, Multimeter Diagnosis & Fix

Fault code L5 on Daikin units (Series FTXM, FTXF, Perfera, Comfora, Sensira, SkyAir, VRV) indicates: Instantaneous overcurrent in the Inverter compressor (IPM Output). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Air Conditioning subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Daikin L5)

Manufacturer / BrandDaikin
Error CodeL5
System / CategoryAir Conditioning
Compatible ModelsSeries FTXM, FTXF, Perfera, Comfora, Sensira, SkyAir, VRV
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsU-V, V-W, U-W compressor windings: 0.8 Ω to 2.5 Ω identical to each other

2. Guided Symptom Troubleshooting Matrix

🔎 Does the compressor try to start with a jerk and stops after 3 seconds marking L5?
✓ Scenario A: Yes (Confirmed)

Disconnect the 3 cables (U, V, W) from the compressor and test again: if it continues to give L5 at no load, the IPM module on the exterior board is burned out.

✕ Scenario B: No (Not Present)

If without a compressor it gives another error, the compressor is mechanically seized or grounded.

3. Step-by-Step Multimeter Testing Procedure (L5)

  1. Safety Power Isolation: Disconnect the Daikin unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault L5 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: U-V, V-W, U-W compressor windings: 0.8 Ω to 2.5 Ω identical to each other.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Daikin Error L5

🔄 Daikin L5 Reset: Cut power 5 minutes before handling the inverter.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Daikin Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Daikin L5?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Daikin Error Code L5

What does Daikin error code L5 mean?

Daikin L5: Instantaneous overcurrent in the Inverter compressor (IPM Output) (Series FTXM, FTXF, Perfera, Comfora, Sensira, SkyAir, VRV). Multimeter Specs: U-V, V-W, U-W compressor windings: 0.8 Ω to 2.5 Ω identical to each other.

How do I reset Daikin fault code L5?

Cut power 5 minutes before handling the inverter.

What multimeter values should I check for Daikin code L5?

U-V, V-W, U-W compressor windings: 0.8 Ω to 2.5 Ω identical to each other