Infrico / Coreco (Frío Hostelería) Error Code Pr1 / Pr2 / E0 / E1: Meaning, Multimeter Diagnosis & Fix

Fault code Pr1 / Pr2 / E0 / E1 on Infrico / Coreco (Frío Hostelería) units (Mesas Refrigeradas, Armarios Refrigerators, Vitrinas Tapas and Abatidores of temperature Infrico, Coreco, Docriluc) indicates: Error of Probe / Sensor of temperature of cámara (Pr1 / E0) or Probe / Sensor of Evaporator (Pr2 / E1) in controlador digital Infrico / Coreco. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Commercial Refrigeration & Catering subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Infrico / Coreco (Frío Hostelería) Pr1 / Pr2 / E0 / E1)

Manufacturer / BrandInfrico / Coreco (Frío Hostelería)
Error CodePr1 / Pr2 / E0 / E1
System / CategoryCommercial Refrigeration & Catering
Compatible ModelsMesas Refrigeradas, Armarios Refrigerators, Vitrinas Tapas and Abatidores of temperature Infrico, Coreco, Docriluc
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsNTC thermistor probe Standard hostelería a 25°C: 10 kΩ | Probe / Sensor PTC KTY81 a 25°C: ~990 Ω - 1.000 Ω

2. Guided Symptom Troubleshooting Matrix

🔎 Does Infrico / Coreco (Frío Hostelería) error code Pr1 / Pr2 / E0 / E1 return immediately after a full power cycle even when main supply voltage is stable?
✓ Scenario A: Yes (Confirmed)

Permanent hardware or sensor circuit fault (Error of Probe / Sensor of temperature of cámara (Pr1 / E0) or Probe / Sensor of Evaporator (Pr2 / E1) in controlador digital Infrico / Coreco). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: NTC thermistor probe Standard hostelería a 25°C: 10 kΩ | Probe / Sensor PTC KTY81 a 25°C: ~990 Ω - 1.000 Ω. If it reads open circuit (OL) or dead short, replace the faulty part.

✕ Scenario B: No (Not Present)

Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: replace la Probe / Sensor of temperature conectada in la regleta trasera of the controlador digital.

3. Step-by-Step Multimeter Testing Procedure (Pr1 / Pr2 / E0 / E1)

  1. Safety Power Isolation: Disconnect the Infrico / Coreco (Frío Hostelería) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Pr1 / Pr2 / E0 / E1 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: NTC thermistor probe Standard hostelería a 25°C: 10 kΩ | Probe / Sensor PTC KTY81 a 25°C: ~990 Ω - 1.000 Ω.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Infrico / Coreco (Frío Hostelería) Error Pr1 / Pr2 / E0 / E1

🔄 Infrico / Coreco (Frío Hostelería) Pr1 / Pr2 / E0 / E1 Reset: replace la Probe / Sensor of temperature conectada in la regleta trasera of the controlador digital.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (NTC Temperature Sensor)?

Check OEM & aftermarket availability for Infrico NTC Temperature Sensor:

Want to use the interactive diagnostic wizard or electrical calculators for Infrico / Coreco (Frío Hostelería) Pr1 / Pr2 / E0 / E1?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Infrico / Coreco (Frío Hostelería) Error Code Pr1 / Pr2 / E0 / E1

What does Infrico / Coreco (Frío Hostelería) error code Pr1 / Pr2 / E0 / E1 mean?

Infrico / Coreco (Frío Hostelería) Pr1 / Pr2 / E0 / E1: Error of Probe / Sensor of temperature of cámara (Pr1 / E0) or Probe / Sensor of Evaporator (Pr2 / E1) in controlador digital Infrico / Coreco (Mesas Refrigeradas, Armarios Refrigerators, Vitrinas Tapas and Abatidores of temperature Infrico, Coreco, Docriluc). Multimeter Specs: NTC thermistor probe Standard hostelería a 25°C: 10 kΩ | Probe / Sensor PTC KTY81 a 25°C: ~990 Ω - 1.000 Ω.

How do I reset Infrico / Coreco (Frío Hostelería) fault code Pr1 / Pr2 / E0 / E1?

replace la Probe / Sensor of temperature conectada in la regleta trasera of the controlador digital.

What multimeter values should I check for Infrico / Coreco (Frío Hostelería) code Pr1 / Pr2 / E0 / E1?

NTC thermistor probe Standard hostelería a 25°C: 10 kΩ | Probe / Sensor PTC KTY81 a 25°C: ~990 Ω - 1.000 Ω