Fault code Sale Water Natural (No Enfría) on Fuentes of Water (Canaletas / Columbia) units (Fuentes of Water Fría of Red and Botellón to Oficinas, Colegios and Fábricas (Canaletas Serie 6/8, M77, Columbia, Eden)) indicates: Water comes out with good flow from the cold spout of the fountain, but it comes out over time (Compressor does not start or ice blocking the coil). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Commercial Refrigeration & Catering subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Fuentes of Water (Canaletas / Columbia) Sale Water Natural (No Enfría))

Manufacturer / BrandFuentes of Water (Canaletas / Columbia)
Error CodeSale Water Natural (No Enfría)
System / CategoryCommercial Refrigeration & Catering
Compatible ModelsFuentes of Water Fría of Red and Botellón to Oficinas, Colegios and Fábricas (Canaletas Serie 6/8, M77, Columbia, Eden)
Severity LevelMedium Severity · Protection Mode
Multimeter SpecsOptimum cold water temperature in fountain: 6°C to 10°C (Avoid going below 4°C due to risk of freezing and breakage of the boiler)

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Can you hear the rear fan of the water fountain, but the water does not come out cold?
βœ“ Scenario A: Yes (Confirmed)

1) Turn the **regulating thermostat** wheel (located behind or inside the lower cabinet): if someone turned it to maximum (position 7), a **solid block of ice forms inside the boiler** that chokes the passage or isolates the sensor; Turn off the source for 4 hours and leave it at **number 3 or 4**. 2) If the bottom black compressor is on fire and 'clicks...mmm...click' every minute without starting: The **PTC start relay or Klixon thermal protector** plugged into the side of the compressor has burned out.

βœ• Scenario B: No (Not Present)

Also clean the black rear grille (condenser) full of lint with a brush.

3. Step-by-Step Multimeter Testing Procedure (Sale Water Natural (No Enfría))

  1. Safety Power Isolation: Disconnect the Fuentes of Water (Canaletas / Columbia) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Sale Water Natural (No Enfría) for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Optimum cold water temperature in fountain: 6°C to 10°C (Avoid going below 4°C due to risk of freezing and breakage of the boiler).
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Fuentes of Water (Canaletas / Columbia) Error Sale Water Natural (No Enfría)

πŸ”„ Fuentes of Water (Canaletas / Columbia) Sale Water Natural (No Enfría) Reset: Clean the rear condensing grille of dust, lower the thermostat to the midpoint (3-4) or replace the compressor PTC relay.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Fuentes of Water Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Fuentes of Water (Canaletas / Columbia) Sale Water Natural (No Enfría)?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Fuentes of Water (Canaletas / Columbia) Error Code Sale Water Natural (No Enfría)

What does Fuentes of Water (Canaletas / Columbia) error code Sale Water Natural (No Enfría) mean?

Fuentes of Water (Canaletas / Columbia) Sale Water Natural (No Enfría): Water comes out with good flow from the cold spout of the fountain, but it comes out over time (Compressor does not start or ice blocking the coil) (Fuentes of Water Fría of Red and Botellón to Oficinas, Colegios and Fábricas (Canaletas Serie 6/8, M77, Columbia, Eden)). Multimeter Specs: Optimum cold water temperature in fountain: 6°C to 10°C (Avoid going below 4°C due to risk of freezing and breakage of the boiler).

How do I reset Fuentes of Water (Canaletas / Columbia) fault code Sale Water Natural (No Enfría)?

Clean the rear condensing grille of dust, lower the thermostat to the midpoint (3-4) or replace the compressor PTC relay.

What multimeter values should I check for Fuentes of Water (Canaletas / Columbia) code Sale Water Natural (No Enfría)?