Fronius (Primo / Symo / Gen24) Β· 2 Verified Diagnostic Sheets
ESENDEFRIT
Energía Solar

Fronius (Primo / Symo / Gen24) Error Codes: Complete List (2 Faults), Causes & Reset

Complete technical directory of all 2 Fronius (Primo / Symo / Gen24) error codes (Energía Solar) with exact meanings, multimeter reference specs, and reset instructions.

Error Code Technical Meaning Multimeter Specs
Fronius (Primo / Symo / Gen24) State 102 / 105Overvoltage or public power grid frequency out of limits (AC Voltage Too High > 253V AC)Legal cut-off limit due to overvoltage in European network in 50549: 253.0V AC (Average 10 min)
Fronius (Primo / Symo / Gen24) State 307 / 522 / 523Low input voltage in solar panels (DC Input Voltage Too Low - Normal at dawn/dusk or DC disconnector failure)Minimum starting voltage Fronius Primo/Symo: > 80V DC (MPPT range: 80V - 800V DC)