Fronius (Primo / Symo / Gen24) Error Code State 102 / 105: Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Fronius (Primo / Symo / Gen24) State 102 / 105)
| Manufacturer / Brand | Fronius (Primo / Symo / Gen24) |
|---|---|
| Error Code | State 102 / 105 |
| System / Category | Energía Solar |
| Compatible Models | Inverters Fotovoltaicos Fronius Primo, Symo, Galvo and Tauro / Gen24 Plus |
| Severity Level | Medium Severity · Protection Mode |
| Multimeter Specs | Legal cut-off limit due to overvoltage in European network in 50549: 253.0V AC (Average 10 min) |
2. Guided Symptom Troubleshooting Matrix
When all the neighbors with solar panels inject energy into the street at the same time or the cable from your inverter to the meter is too thin, **the voltage at the AC terminals of the inverter exceeds 253V AC (the legal limit of 10% over 230V)** and the inverter cuts off by law for 60 seconds.
1) Check that the AC circuit breaker and inverter differential screws are tight. 2) If the cable between the inverter and the main panel is longer than 15 meters and is 4 mm² or 6 mm², change it to a section of **10 mm²** to eliminate the voltage drop/surge.
3. Step-by-Step Multimeter Testing Procedure (State 102 / 105)
- Safety Power Isolation: Disconnect the Fronius (Primo / Symo / Gen24) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault State 102 / 105 for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Legal cut-off limit due to overvoltage in European network in 50549: 253.0V AC (Average 10 min).
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Fronius (Primo / Symo / Gen24) Error State 102 / 105
Check OEM & aftermarket availability for Fronius Replacement Sensor / Part:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Fronius (Primo / Symo / Gen24) Error Code State 102 / 105
What does Fronius (Primo / Symo / Gen24) error code State 102 / 105 mean?
Fronius (Primo / Symo / Gen24) State 102 / 105: Overvoltage or public power grid frequency out of limits (AC Voltage Too High > 253V AC) (Inverters Fotovoltaicos Fronius Primo, Symo, Galvo and Tauro / Gen24 Plus). Multimeter Specs: Legal cut-off limit due to overvoltage in European network in 50549: 253.0V AC (Average 10 min).
How do I reset Fronius (Primo / Symo / Gen24) fault code State 102 / 105?
Increase the section of the AC cable between the inverter and the main panel (minimum 6 mm² - 10 mm²) or activate the power reduction function due to voltage Q(U) / P(U).
What multimeter values should I check for Fronius (Primo / Symo / Gen24) code State 102 / 105?
Legal cut-off limit due to overvoltage in European network in 50549: 253.0V AC (Average 10 min)