Freidora Gas / Electric (Frymaster / Movilfrit) Error Code No Aguanta Flame Piloto / No Enciende: Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Freidora Gas / Electric (Frymaster / Movilfrit) No Aguanta Flame Piloto / No Enciende)
| Manufacturer / Brand | Freidora Gas / Electric (Frymaster / Movilfrit) |
|---|---|
| Error Code | No Aguanta Flame Piloto / No Enciende |
| System / Category | Commercial Refrigeration & Catering |
| Compatible Models | Freidoras Industriales of Hostelería a Gas (valve Robertshaw / Sit) and Electric Trifásicas |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | voltage Termopila (Two-wire generator) in open circuit with Flame piloto: > 600 mV - 750 mV DC (Con carga conectada: > 350 mV DC) |
2. Guided Symptom Troubleshooting Matrix
Permanent hardware or sensor circuit fault (La Flame piloto of the freidora a gas se apaga in cuanto sueltas el Button or los quemadores principales no abren (Termopar or Termopila)). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: voltage Termopila (Two-wire generator) in open circuit with Flame piloto: > 600 mV - 750 mV DC (Con carga conectada: > 350 mV DC). If it reads open circuit (OL) or dead short, replace the faulty part.
Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: press el Button rojo of rearme of the high-limit safety thermostat (Hi-Limit) bajo la cuba and clean la punta of the termopila.
3. Step-by-Step Multimeter Testing Procedure (No Aguanta Flame Piloto / No Enciende)
- Safety Power Isolation: Disconnect the Freidora Gas / Electric (Frymaster / Movilfrit) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault No Aguanta Flame Piloto / No Enciende for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: voltage Termopila (Two-wire generator) in open circuit with Flame piloto: > 600 mV - 750 mV DC (Con carga conectada: > 350 mV DC).
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Freidora Gas / Electric (Frymaster / Movilfrit) Error No Aguanta Flame Piloto / No Enciende
Check OEM & aftermarket availability for Freidora Gas Replacement Sensor / Part:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Freidora Gas / Electric (Frymaster / Movilfrit) Error Code No Aguanta Flame Piloto / No Enciende
What does Freidora Gas / Electric (Frymaster / Movilfrit) error code No Aguanta Flame Piloto / No Enciende mean?
Freidora Gas / Electric (Frymaster / Movilfrit) No Aguanta Flame Piloto / No Enciende: La Flame piloto of the freidora a gas se apaga in cuanto sueltas el Button or los quemadores principales no abren (Termopar or Termopila) (Freidoras Industriales of Hostelería a Gas (valve Robertshaw / Sit) and Electric Trifásicas). Multimeter Specs: voltage Termopila (Two-wire generator) in open circuit with Flame piloto: > 600 mV - 750 mV DC (Con carga conectada: > 350 mV DC).
How do I reset Freidora Gas / Electric (Frymaster / Movilfrit) fault code No Aguanta Flame Piloto / No Enciende?
press el Button rojo of rearme of the high-limit safety thermostat (Hi-Limit) bajo la cuba and clean la punta of the termopila.
What multimeter values should I check for Freidora Gas / Electric (Frymaster / Movilfrit) code No Aguanta Flame Piloto / No Enciende?
voltage Termopila (Two-wire generator) in open circuit with Flame piloto: > 600 mV - 750 mV DC (Con carga conectada: > 350 mV DC)