Envasadora Vacío (Sammic / Orved / Audion) Error Code No Hace Vacío (La Bolsa Queda Floja): Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Envasadora Vacío (Sammic / Orved / Audion) No Hace Vacío (La Bolsa Queda Floja))
| Manufacturer / Brand | Envasadora Vacío (Sammic / Orved / Audion) |
|---|---|
| Error Code | No Hace Vacío (La Bolsa Queda Floja) |
| System / Category | Commercial Refrigeration & Catering |
| Compatible Models | Envasadoras al Vacío of Campana Profesionales Sammic (SE, SU), Orved, Henkelman, Audionvac, TekVac |
| Severity Level | Medium Severity · Protection Mode |
| Multimeter Specs | Busch/Sammic vacuum pump oil: ISO VG 32 / VG 100 (Change every 150-300 hours or when it turns whitish) |
2. Guided Symptom Troubleshooting Matrix
Key physical explanation: the machine makes a vacuum in **the entire hood**. If the bag is left with air it is due to one of these 2 things: 1) **You have placed the neck of the bag incorrectly and the sealing bar has sealed the bag at the beginning or you have covered the suction hole at the bottom of the tank**. 2) **The oil in the vacuum pump is milky white (emulsified with water and steam from sauces)** or low level, so the pump only reaches 70% vacuum instead of 99.8%. Look through the side/rear porthole: the oil should be clear like sunflower oil; If it looks like white milk, change it today for **SAE 10 / ISO VG 32 Vacuum Hydraulic Oil (without detergents)**.
Also check that the **black rubber on the edge of the methacrylate lid** does not have a pinch through which air can enter whistling.
3. Step-by-Step Multimeter Testing Procedure (No Hace Vacío (La Bolsa Queda Floja))
- Safety Power Isolation: Disconnect the Envasadora Vacío (Sammic / Orved / Audion) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault No Hace Vacío (La Bolsa Queda Floja) for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Busch/Sammic vacuum pump oil: ISO VG 32 / VG 100 (Change every 150-300 hours or when it turns whitish).
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Envasadora Vacío (Sammic / Orved / Audion) Error No Hace Vacío (La Bolsa Queda Floja)
Check OEM & aftermarket availability for Envasadora Vacío Replacement Sensor / Part:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Envasadora Vacío (Sammic / Orved / Audion) Error Code No Hace Vacío (La Bolsa Queda Floja)
What does Envasadora Vacío (Sammic / Orved / Audion) error code No Hace Vacío (La Bolsa Queda Floja) mean?
Envasadora Vacío (Sammic / Orved / Audion) No Hace Vacío (La Bolsa Queda Floja): The vacuum pump sounds for 30 seconds and the lid goes down, but when the bag is opened it still has air inside (Envasadoras al Vacío of Campana Profesionales Sammic (SE, SU), Orved, Henkelman, Audionvac, TekVac). Multimeter Specs: Busch/Sammic vacuum pump oil: ISO VG 32 / VG 100 (Change every 150-300 hours or when it turns whitish).
How do I reset Envasadora Vacío (Sammic / Orved / Audion) fault code No Hace Vacío (La Bolsa Queda Floja)?
Change the emulsified oil in the vacuum pump (SAE 10 / ISO VG 32) and check the rubber gasket of the methacrylate cover.
What multimeter values should I check for Envasadora Vacío (Sammic / Orved / Audion) code No Hace Vacío (La Bolsa Queda Floja)?
Busch/Sammic vacuum pump oil: ISO VG 32 / VG 100 (Change every 150-300 hours or when it turns whitish)