Compressor Industrial (Atlas Copco / Abac / Puska) Error Code overload Motor (Relé Thermal F21): Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Compressor Industrial (Atlas Copco / Abac / Puska) overload Motor (Relé Thermal F21))
| Manufacturer / Brand | Compressor Industrial (Atlas Copco / Abac / Puska) |
|---|---|
| Error Code | overload Motor (Relé Thermal F21) |
| System / Category | Commercial Refrigeration & Catering |
| Compatible Models | Compresores of Tornillo GX, GA, Abac Spinn / Genesis, Puska RTA (Controlador Elektronikon) |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | voltage trifásica equilibrada: 400V AC ±5% between L1-L2-L3 |
2. Guided Symptom Troubleshooting Matrix
Permanent hardware or sensor circuit fault (Disparo of the relé Thermal of overload of the motor principal or of the Fan (Motor Overload)). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: voltage trifásica equilibrada: 400V AC ±5% between L1-L2-L3. If it reads open circuit (OL) or dead short, replace the faulty part.
Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: press el Button azul of rearme físico in el relé Thermal F21 of the cuadro of contactores and luego Reset in display.
3. Step-by-Step Multimeter Testing Procedure (overload Motor (Relé Thermal F21))
- Safety Power Isolation: Disconnect the Compressor Industrial (Atlas Copco / Abac / Puska) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault overload Motor (Relé Thermal F21) for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: voltage trifásica equilibrada: 400V AC ±5% between L1-L2-L3.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Compressor Industrial (Atlas Copco / Abac / Puska) Error overload Motor (Relé Thermal F21)
Check OEM & aftermarket availability for Compressor Industrial Replacement Sensor / Part:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Compressor Industrial (Atlas Copco / Abac / Puska) Error Code overload Motor (Relé Thermal F21)
What does Compressor Industrial (Atlas Copco / Abac / Puska) error code overload Motor (Relé Thermal F21) mean?
Compressor Industrial (Atlas Copco / Abac / Puska) overload Motor (Relé Thermal F21): Disparo of the relé Thermal of overload of the motor principal or of the Fan (Motor Overload) (Compresores of Tornillo GX, GA, Abac Spinn / Genesis, Puska RTA (Controlador Elektronikon)). Multimeter Specs: voltage trifásica equilibrada: 400V AC ±5% between L1-L2-L3.
How do I reset Compressor Industrial (Atlas Copco / Abac / Puska) fault code overload Motor (Relé Thermal F21)?
press el Button azul of rearme físico in el relé Thermal F21 of the cuadro of contactores and luego Reset in display.
What multimeter values should I check for Compressor Industrial (Atlas Copco / Abac / Puska) code overload Motor (Relé Thermal F21)?
voltage trifásica equilibrada: 400V AC ±5% between L1-L2-L3